Strata CT Installation

Site Requirements

Input Power

The Strata CT requires an input power source of 240±20VAC, 50/60 Hz, single phase. The
system requires one or two AC outlets that must be dedicated to system use, fused, and
earthed.
Each Remote Expansion Cabinet requires 3.2 amps. maximum. The remote cabinet
installation requires one or two AC outlets that must be dedicated to system use, fused, and
grounded.
See Cabinet Installation Considerations for complete AC power cabling, ground wiring and
battery installation instructions for local and remote cabinets.
CAUTION!
A reserve power source (two or four customer-supplied 12VDC batteries) may be connected
to the Strata CT to serve as a backup in case of power failure.
H
Separate reserve power may be required for remote expansion cabinets.

Clearance and Location

The Base and optional Expansion Cabinets may be either floor or wall mounted.
shows the minimum clearance requirements for up to five cabinets.
C
Notes
When selecting a location for the cabinets, the location must be:
The location must not be:
Optional customer-supplied reserve batteries require a well-ventilated location close (within
nine feet) to the Strata CT cabinets.
2-2
To avoid accidental power turn-off, it is recommended that an On/Off
wall switch not be used on AC circuits dedicated for the use of Strata CT.
Floor mounting requires the following additional hardware:
G
BFIF – floor mounting stands and brackets.
G
BCCB – electrical conduit box, if three or more cabinets are installed.
G
Wall mounting requires a plywood (3/4 inch thick) backboard.
G
N
Dry and clean
N
Well-ventilated
N
Well-illuminated
N
Easily accessible
N
Subject to extreme heat or cold
N
Subject to corrosive fumes, dust, or other airborne contaminants
N
Subject to excessive vibration
N
Next to television, radio, office automation, or high frequency equipment