Finally, pressing the Fast Selection Key will remove the Fast Selection Window until it is needed again.
As you can see, the Fast Selection window, though not seen, is always readily available.

Sys tem Mes sage Win dow

EasyBuilder has two Windows designated as System Message windows - Window #5 is designated as the PLC
Response Window that pops up automatically when the OIT loses communications with the PLC.
Window #6 is designated as the HMI Response window, which will pop up automatically with the OIT loses
communications with a another OIT that is remotely connected.
Both of these windows have been pre-configured with automated messages and a function key to close the window,
so no changes are necessary.
The Fast Selection window can only call full screen windows not popup windows.
Therefore, you cannot use Function Key objects with the Popup Window attribute in
Fast Selection windows.