Fuser Unit

Removing the Old Fuser Unit
Xerox WorkCentre 7132 User Guide
Downloaded From ManualsPrinter.com Manuals
5.
Close the side cover.
6.
Select [Reset Counter] on the
screen.
7.
Select [Yes] to reset the counter.
The fuser unit lasts approximately 100,000 copies and prints. The machine will display
a warning message approximately 1,500 copies and prints before the unit reaches the
end of its life. Another message will be displayed when the unit needs to be replaced.
CAUTION: The left-hand cover should not be opened while the machine is operating.
If the left-hand cover is opened, the machine automatically stops. Push firmly to close
the cover, as it may become difficult to close. Follow the messages on the screen, if
present, to remove any paper jammed in the machine.
1.
Select [Fuser] on the [Supplies] screen or the [Consumables Status] screen.
2.
Turn the power off, unplug the
machine, and allow the machine
to cool for approximately 30
minutes.
3.
Pull the side cover open.
SMart Kit (Customer Replaceable Units)