b. Twist the battery (either clockwise or counter-clockwise) and lift it out.
FIGURE 4-11
4.6.2
Install Battery
1. Unpack the replacement battery and place it on an antistatic mat.
2. Press the new battery into the battery holder with the positive side (+) facing
the server chassis side wall.
3. If the service processor is configured to synchronize with a network time server
using the Network Time Protocol (NTP), the ILOM clock will be reset as soon as
the server is powered on and connected to the network. Otherwise, proceed to
the next step.
4. If the service processor is not configured to use NTP, you must reset the ILOM
clock using the ILOM CLI or the web interface.
For instructions, see the Sun Integrated Lights Out Manager (ILOM) 3.0
Documentation Collection.
5. Return the server to operation.
4-26
Sun Fire X4270 M2 Server Service Manual • May 2011