b. To disconnect the cables from the HBA PCIe card, press the latch, push in
4. Remove the SAS expander board and disconnect the SAS cables.
See
5. Remove the SAS cables from the server.
Be careful not to snag the cables on the server components.
5.10.2
Install Storage Drive Cable in a SAS Configuration
1. Reconnect the SAS cables to the SAS expander board.
See
2. Route the cables through the server as shown in the applicable cabling diagram
(
FIGURE 5-12
3. Plug the cable connectors into the connectors on the HBA card from which the
SAS cables were removed.
4. Press the cables in the cable tie down and secure the cable with the tie down.
5. Return the server to operation.
a. Install the top cover.
b. Return the server to the normal rack position.
c. Reconnect the power cord (or cords) to the power supply (or supplies) and
5.10.3
Remove Power Distribution Board Cable
1. Prepare the server for service.
a. Power off the server and disconnect the power cord (or cords) from the power
5-34
Sun Fire X4270 M2 Server Service Manual • May 2011
toward the connector, and then pull out to remove the cables.
Section 5.2.1, "Remove the SAS Expander Board" on page
Section 5.2.2, "Install SAS Expander Board" on page
or
FIGURE 5-13
See
Section 6.2, "Installing the Server Top Cover" on page
See
Section 6.4, "Returning the Server to the Normal Rack Position" on
page
6-5.
power on the server.
See
Section 6.5, "Powering On the Server" on page
Verify that the AC Present LED is lit.
supply (or supplies).
See
Section 2.4.2, "Power Off the Server" on page
).
5-3.
5-6.
6-2.
6-7.
2-4.