c. Reconnect the power cord (or cords) to the server power supply (or supplies)
6. Use ILOM to clear DDR3 DIMM faults.
For instructions for clearing DIMM faults, see the Oracle Integrated Lights Out
Manager (ILOM) 3.0 Supplement for Sun Fire X4170 M2 and X4270 M2 Servers
(821-0489).
4.2.8
Error Correction and Parity
The server's processor provides parity protection on its internal cache memories and
error-correcting code (ECC) protection of the data. The system can detect and log to
the ILOM event log the following types of errors:
Correctable and uncorrectable memory ECC errors
■
Uncorrectable CPU internal errors
■
Advanced ECC corrects up to 4 bits in error on nibble boundaries, as long as they are
all in the same DRAM. If a DRAM fails, the DIMM continues to function.
For instructions for clearing DIMM faults, see the Oracle Integrated Lights Out Manager
(ILOM) 3.0 Supplement for Sun Fire X4170 M2 and X4270 M2 Servers (821-0489).
4.3
Servicing the Air Baffle
You must remove the air baffle when removing and installing the motherboard on
Sun Fire X4270 M2 Server.
Caution – To prevent the system from overheating, ensure that the air baffle is
correctly installed before powering on the server.
Caution – Ensure that all power is removed from the server before removing or
installing DIMMs, or damage to the DIMMs might occur. You must disconnect all
power cables from the system before performing this procedure.
and power on the server.
See
Section 6.5, "Powering On the Server" on page
Verify that the AC Present LED is lit.
6-7.
Chapter 4
Servicing Motherboard Components
4-13