2.5.8

Updating the BIOS Firmware

The BIOS is updated whenever you update the Oracle ILOM SP firmware. For
instructions about updating the firmware, refer to the Oracle Integrated Lights Out
Manager (ILOM) 3.0 Documentation Collection.
2.6
Extending the Server to the Maintenance
Position
The following components can be serviced with the server in the maintenance
position:
Storage drives
Fan modules
Power supplies
Fan board
DDR3 DIMMs
PCIe risers
PCIe cards
Disk Backplane
Motherboard battery
If the server is installed in a rack with extendable slide rails, use this procedure to

extend the server to the maintenance position.

2.6.1
Extend the Server to the Maintenance Position
1. Verify that no cables will be damaged or will interfere when the server is
extended.
Although the cable management arm (CMA) that is supplied with the server is
hinged to accommodate extending the server, you should ensure that all cables
and cords are capable of extending.
2. From the front of the server, release the two slide release latches (
Squeeze the green slide release latches to release the slide rails.
2-26
Sun Fire X4270 M2 Server Service Manual • May 2011
).
FIGURE 2-12