When or where the error occurred
TABLE 2-3
POST diagnostics along with instructions for how to possibly resolve the error
reported.
BIOS POST F1 and F2 Error Messages
TABLE 2-3
BIOS POST Error Message
Uncorrectable Error Detected on Last
Boot:IOH(0) Protocol Error (Please Check SP Log
for more Details)
Uncorrectable Error Detected on Last
Boot:IOH(0) QPI [x] Error (Please Check SP Log
for more Details)
Uncorrectable Error Detected on Last
Boot:IOH(0) PCI-E [x] Error (Please Check SP
Log for more Details)
Uncorrectable Error Detected on Last
Boot:IOH(0) ESI Error (Please Check SP Log for
more Details)
Uncorrectable Error Detected on Last
Boot:IOH(0) Thermal Error (Please Check SP
Log for more Details)
Uncorrectable Error Detected on Last
Boot:IOH(0) DMA Error (Please Check SP Log
for more Details)
Uncorrectable Error Detected on Last
Boot:IOH(0) Miscellaneous Error (Please Check
SP Log for more Details)
Uncorrectable Error Detected on Last
Boot:IOH(0) VTd Error (Please Check SP Log for
more Details)
BMC Not Responding
2-8
Sun Fire X4270 M2 Server Service Manual • May 2011
lists some of the F1 and F2 error messages that could appear during the
Error Type
IOH error
IOH error
IOH error
IOH error
IOH error
IOH error
IOH error
IOH error
ILOM error
Resolution
• Press F1 to continue.
• Check the SP event log in ILOM for more
details.
• Press F1 to continue.
• Check the fault management function and
the SP event log in ILOM for more details.
Note - Where QPI [x] equals 0 for QPI Link 0
or 1 for QPI Link 1.
• Press F1 to continue.
• Check the fault management function and
the SP event log in ILOM for more details.
Note - Where PCI-E [x] port number can
range from 1 to 10 depending on the PCI root
port on IOH.
• Press F1 to continue.
• Check the fault management function and
the SP event log in ILOM for more details.
• Press F1 to continue.
• Check the fault management function and
the SP event log in ILOM for more details.
• Press F1 to continue.
• Check the SP event log for more details.
• Press F1 to continue.
• Check the fault management function and
the SP event log in ILOM for more details.
• Press F1 to continue.
• Check the SP event log in ILOM for more
details.
• Press F1 to continue.
Note - This error message might display if
during the SP/BIOS communication an
internal error occurs. This error might require
you to restart the SP.

Advertisement