f. Connect the LED/USB flex cable to the connector board [1].
2. If you removed the left LED module from a server with 2.5-inch storage drives,
install the server's front cover.
See
3. Return the server to operation.
a. Install the top cover.
b. Return the server to the normal rack position.
c. Reconnect the power cord (or cords) to the power supply (or supplies) and
5.5.3
Remove the Left LED Module
1. Prepare the server for service.
a. Power off the server and disconnect the power cord (or cords) from the power
b. Extend the server to the maintenance position.
c. Attach an antistatic wrist strap.
d. Remove the top cover.
e. If you are removing the LED Module from a server with 2.5-inch storage
2. Remove the left LED Module (
5-16
Sun Fire X4270 M2 Server Service Manual • May 2011
Section 6.1.1, "Install the Server Front Cover" on page
See
Section 6.2, "Installing the Server Top Cover" on page
See
Section 6.4, "Returning the Server to the Normal Rack Position" on
page
6-5.
power on the server.
See
Section 6.5, "Powering On the Server" on page
Verify that the AC Present LED is lit.
supply (or supplies).
See
Section 2.4.2, "Power Off the Server" on page
See
Section 2.6, "Extending the Server to the Maintenance Position" on
page
2-26.
See
Section 2.9, "Performing Electrostatic Discharge and Antistatic Prevention
Measures" on page
2-31.
See
Section 2.10, "Removing the Server's Top Cover" on page
drives, remove the server's front cover.
See
Section 2.11, "Removing the Front Cover From a Server with 2.5-Inch
Storage Drives" on page
2-35.
).
FIGURE 5-7
6-2.
6-2.
6-7.
2-4.
2-33.