  • Page 1 Sun Blade X4-2B Service Manual Part No: E37039–04 March, 2014...
  • Page 2 Copyright ©2013-2014 500 Oracle Parkway, Redwood City, CA 94065 U.S.A. This software and related documentation are provided under a license agreement containing restrictions on use and disclosure and are protected by intellectual property laws. Except as expressly permitted in your license agreement or allowed by law, you may not use, copy, reproduce, translate, broadcast, modify, license, transmit, distribute, exhibit, perform, publish, or display any part, in any form, or by any means.
  • Page 3: Table Of Contents

    Access to Oracle Support .......................7 Contributors ............................7 Change History ..........................7 Service Manual Overview ........................9 About the Sun Blade X4-2B ........................ 11 Product Description ........................11 About Front and Rear Panels ...................... 12 About the Chassis ......................... 21 About System Components ......................24 Troubleshooting the Server Module ....................
  • Page 4 BIOS Main Menu Selections ..................... 147 BIOS Advanced Menu Selections ..................... 155 BIOS I/O Menu Selections ......................165 BIOS Boot Menu Selections ...................... 173 BIOS Save and Exit Menu Selections ..................175 Index ..............................177 Sun Blade X4-2B Service Manual • March, 2014...
  • Page 5: Using This Documentation

    (blade), and blade chassis are updated periodically. You can obtain the latest version in one of three ways: Oracle System Assistant – This is a factory-installed option for Sun Oracle x86 servers. It has ■ all the tools and drivers you need and resides on a USB drive installed in most servers.
  • Page 6: Documentation And Feedback

    You can generate a PDF that includes all information about a particular topic subject (such as hardware installation or product notes) can be generated by clicking the PDF button in the upper left corner of the HTML page. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 7: Support And Training

    Change History Support and Training These web sites provide additional resources: Support: ■ http://support.oracle.com Training: ■ http://education.oracle.com Access to Oracle Support Oracle customers have access to electronic support through My Oracle Support. For information, visit or visit http://www.oracle.com/pls/topic/lookup?ctx=acc&id=info if you are hearing impaired. http://www.oracle.com/pls/topic/lookup?ctx=acc&id=trs Contributors Primary Authors: Lisa Kuder, Ray Angelo, Mark McGothigan.
  • Page 9: Service Manual Overview

    Service Manual Overview The Sun Blade X4-2B Service Manual contains service and maintenance procedures for the Sun Blade X4-2B server module. The major sections of this manual are described in the following table. Description Link Overview of the server module features and “About the Sun Blade X4-2B”...
  • Page 11: About The Sun Blade X4-2B

    E5-2600 V2 processor family), and 24 DIMM slots for a maximum of 768 GB of memory. The blade server module is inserted in to a Sun Blade 6000 chassis, which provides power and cooling to the blades. The Sun Blade X4-2B server module is an ideal blade for building enterprise cloud infrastructures.
  • Page 12: About Front And Rear Panels

    “Rear Panel of the Server Module” on page 17 ■ “UCP and the Multi-Port Dongle Cable” on page 19 ■ Front Panel Features The following illustration shows front panel features on the Sun Blade X4-2B. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 13 “Front Panel Indicators and Buttons” on page 13 Front Panel Indicators and Buttons The topics included in this section show the location of the Sun Blade X4-2B front panel indicators and buttons and describe their functions. Location of Front Panel Indicators and Buttons...
  • Page 14 Ready To Remove Indicator – Blue Service Action Required Indicator – Amber Power Button Power OK Indicator – Green NMI Button – Service use only Detailed descriptions and functions follow. Locate Indicator Button Sun Blade X4-2B Service Manual • March, 2014...
  • Page 15 Front Panel Indicators and Buttons Function: Combination white indicator and button. ■ Activate the Locate Indicator remotely from Oracle ILOM to identify a server module ■ within a chassis. Press and hold the Locate Indicator button to activate the front panel lamp test. ■...
  • Page 16 Standby power state (SP booted): Blink 0.2 seconds on, 2.8 seconds off ■ Full power state: On solid (does not blink) ■ For more information, see “About Server Power States and Resets” on page ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 17: Nmi Button

    See Also: “About Front and Rear Panels” on page 12 ■ “Rear Panel of the Server Module” on page 17 ■ Rear Panel of the Server Module The following illustration shows the rear panel features on the Sun Blade X4-2B.
  • Page 18 USB flash sticks 2, 3 (P0 and P1) See Also: “About Front and Rear Panels” on page 12 ■ “Front Panel Indicators and Buttons” on page 13 ■ “The System Chassis” on page 21 ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 19 UCP and the Multi-Port Dongle Cable UCP and the Multi-Port Dongle Cable The universal connector port (UCP) and the multi-port dongle cable provide a front panel local access point to the server module boot screen, the BIOS Setup Utility, the Oracle ILOM CLI, and Oracle System Assistant.
  • Page 20 Your chassis might ship with a DB-9-to-RJ-45 serial cable adapter. The adapter allows Note – you to attach a serial cable with a DB-9 connector to the server module using the RJ-45 port on the multi-port cable. See Also: Sun Blade X4-2B Service Manual • March, 2014...
  • Page 21: About The Chassis

    ■ The System Chassis The Sun Blade X4-2B is used in a Sun Blade 6000 modular system chassis. When fully loaded, the chassis can hold a combination of up to ten storage modules and server modules. Server modules draw more power than storage modules, so power limitations apply to the number of...
  • Page 22 The Chassis Monitoring Module (CMM) For more information about the Sun Blade X4-2B configuration and compatibility, see “Supported Hardware” in Sun Blade X4-2B Product Notes See Also: Sun Blade 6000 Modular System Chassis documentation (http://www.oracle.com/pls/ ■ topic/lookup?ctx=sb6000) “The Chassis Monitoring Module (CMM) ” on page 22 ■...
  • Page 23 About Oracle ILOM See Also: Sun Blade 6000 Modular System documentation (http://docs.oracle.com/cd/ ■ E19938-01/index.html) “About Oracle ILOM ” on page 23 ■ Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation Collection ■ (http://www.oracle.com/pls/topic/lookup?ctx=ilom31). About Oracle ILOM Oracle's x86- and SPARC-based servers have an embedded service processor (SP) that contains a preinstalled system management firmware called Oracle Integrated Lights Out Manager (Oracle ILOM).
  • Page 24: About System Components

    “Replaceable Components (FRUs and CRUs)” on page 26 ■ “Component Serviceability” on page 26 ■ Some Sun Blade X4-2B components are optional. Your server module might not contain Note – every replaceable component. Illustrated Parts Breakdown The following illustration and table identifies the replaceable components for the Sun Blade X4-2B: Sun Blade X4-2B Service Manual •...
  • Page 25 Illustrated Parts Breakdown Call Out Description Call Out Description Storage drives (4 maximum, HDD or USB 2.0 sticks (0 and 1) SSD) RAID expansion module (REM) DIMMs DDR3 LV (24 maximum) Processors (0 and 1) System battery (type: CR2032 ) Heat sink assemblies (0 and 1) Server module enclosure (Includes motherboard, disk backplane, and...
  • Page 26 Replaceable Components (FRUs and CRUs) Replaceable Components (FRUs and CRUs) The replaceable components in your Sun Blade X4-2B are designated as either field-replaceable units (FRU) or customer-replaceable units (CRU). A part designated as a FRU must be replaced by an Oracle-qualified service technician.
  • Page 27 Component Serviceability Component Description Serviceability Cold Cold Processor and heat sink assembly (CPU) Cold Motherboard and blade enclosure assembly Cold See Also: “About System Components” on page 24 ■...
  • Page 29: Troubleshooting The Server Module

    Troubleshooting the Server Module These sections introduce the diagnostic tools and strategies available to help you diagnose problems with the Sun Blade X4-2B. Description Link Troubleshoot server “Troubleshooting Server hardware problems. Module Hardware Faults” on page 29 Find additional “Troubleshooting and troubleshooting and Diagnostic Information”...
  • Page 30 Return the server to service . “Returning the Server Module to Operation ” on page 127 Before placing the server module into the chassis, prepare the work space, ensuring ESD protection for the server and components. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 31 Service Troubleshooting Task List Step Task Link Clear the fault in Oracle ILOM. “About Oracle ILOM ” on page 23 Optional: Depending on the component, you might need to clear the fault in Oracle ILOM. Next Steps: “Troubleshoot Hardware Faults” on page 31 ■...
  • Page 32 View specific information by clicking Open Problems in the left navigation panel. The Open Problems screen provides detailed information about the issue, such as the time the event occurred, the component, the subsystem, and a description. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 33 Service Troubleshooting Task List In the following example, the Open Problems screen indicates that a problem has occurred on blade 2 (BL2): View the System Log. The System Log provides additional detailed information about the error (event), including the severity, the component or subsystem, and the date and time the event occurred. Access the server module Oracle ILOM.
  • Page 34 Click the Open Problems link in the left navigation panel. The Open Problems screen provides detailed information about the issue, such as the time the event occurred, the component, the subsystem, and a description. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 35 Service Troubleshooting Task List In the following example, the Open Problems screen indicates that DIMM 8 on CPU 0 has an uncorrectable ECC fault. In this example, the hardware fault with DIMM 8 of CPU 0 on blade 2 (BL2) requires local access to the server. View the System Log.
  • Page 36: Diagnostic Tools

    Oracle VTS software – This application exercises the system, provides hardware ■ validation, and discloses possible faulty components with recommendations for repair. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 37: Troubleshooting And Diagnostic Information

    The following table lists diagnostic and troubleshooting-related procedures and references that can assist you with resolving server issues. Information About: Link Dagnostic tools for the Sun Blade X4-2B server and x86 Diagnostics Guide other X-4 series servers, including procedures for performing runtime and firmware-based tests, using...
  • Page 38: Gather Service Information

    You might need it when contacting Oracle. You can find the SysSN in the following locations: Oracle System Assistant System Information (Home) screen ■ Oracle ILOM Summary screen ■ Server module front panel as shown in the following figure: ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 39: Troubleshoot Server Module Power Problems

    Locate the Server Module Serial Number Related Information: “About Front and Rear Panels” on page 12 ■ “Powering Down the Server Module” on page 47 ■ ■ http://www.oracle.com/goto/x86AdminDiag/docs ■ http://www.oracle.com/goto/ILOM/docs ▼ Troubleshoot Server Module Power Problems If the server module does not power on to either a full power or standby power state, the issue might be related to Sun Blade 6000 Chassis power limitations.
  • Page 40 For more information about the Oracle ILOM system event log or monitoring power consumption, refer to the Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation Collection (http://www.oracle.com/pls/topic/lookup?ctx=ilom31). Sun Blade X4-2B Service Manual • March, 2014...
  • Page 41: About The Dimm And Processor Test Circuit

    About the DIMM and Processor Test Circuit Verify that the Oracle ILOM CMM power management settings for PSUs is configured to default settings, to avoid power loss. “Service Troubleshooting Task List” on page 30 See Also ■ “Troubleshooting and Diagnostic Information” on page 37 ■...
  • Page 42 After a series of messages, the flash process finishes, and the preboot prompt appears. Preboot> To restart the SP, type: Preboot> reset The preboot menu exits and Oracle ILOM boots. Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation Collection See Also ■ (http://www.oracle.com/pls/topic/lookup?ctx=ilom31) Sun Blade X4-2B Service Manual • March, 2014...
  • Page 43: Preparing For Service

    Preparing for Service These sections describe how to safely prepare the Sun Blade X4-2B for service and component removal and replacement: Description Link Before working with components within the server, “Preparing the Server Module for Component power down the server module and prepare for Replacement”...
  • Page 44 This procedure shows both Oracle ILOM web and CLI interface methods. The procedure Note – can be performed using only Oracle ILOM CLI interface. For more information about Oracle ILOM, refer to the Oracle ILOM documentation at http://www.oracle.com/goto/ILOM/docs. To prepare the server for service: Sun Blade X4-2B Service Manual • March, 2014...
  • Page 45 Preparing for Service Power down the server module to standby power. “Powering Down the Server Module” on page 47 for detailed instructions. a. Access Oracle ILOM web interface. Type the IP address into a web browser and log in as a user with root or administrator privileges.
  • Page 46 “Remove the Server Module from the Sun Blade Chassis” on page Insert a server module filler panel into the the vacant server module slot immediately. “Install Server Module Filler Panels” on page Sun Blade X4-2B Service Manual • March, 2014...
  • Page 47: Powering Down The Server Module

    About Server Power States and Resets Remove the server module cover. “Remove the Server Module Top Cover” on page “Servicing Server Module Components ” on page 63 Next Steps ■ “Returning the Server Module to Operation ” on page 127 ■...
  • Page 48: Standby Power

    To perform a graceful shutdown, use the server OS shutdown procedure or the Oracle ILOM graceful power off option. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 49 About Server Power States and Resets Immediate Shutdown An immediate shutdown of the server (also referred to as an emergency shutdown) should be used only in situations when you know that the loss of data is nonexistent or acceptable. An immediate shutdown does not warn users, does not close files, nor does it prepare the file system for shut down to standby power mode.
  • Page 50 Physical access to the server front panel is required. Before You Begin ■ “Front Panel Indicators and Buttons” on page 13 ■ Use this procedure to immediately power off the server. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 51 About Server Power States and Resets Use a stylus to press and hold the Power button for at least five seconds until the full power is off and the server module enters standby power mode. Verify that the full power is off, and that the OK indicator on the front panel blinks, indicating that the server module is in standby power mode.
  • Page 52 This procedure is performed locally requiring physical access to the server. ■ Before You Begin Sun Blade X4-2B Service Manual • March, 2014...
  • Page 53: Performing Esd And Anti-Static Prevention Measures

    Performing ESD and Anti-static Prevention Measures Place the server module in standby power mode. “Powering Down the Server Module” on page To unlock the server module ejector arms, squeeze together the green tabs on the ends of ejector arms. To disengage the server module from the chassis internal connector, rotate both ejector arms away from the server module at the same time until they are fully extended.
  • Page 54 Anti-static bag used to wrap an Oracle replacement part ■ An ESD mat ■ A disposable ESD mat (shipped with some replacement parts or optional system ■ components) Sun Blade X4-2B Service Manual • March, 2014...
  • Page 55: Remove The Server Module From The Sun Blade Chassis

    Performing ESD and Anti-static Prevention Measures Attach an anti-static wrist strap. When servicing or removing server module components, attach an anti-static strap to your wrist and then to a bare metal area on the chassis, server module, or blade. “Remove the Server Module from the Sun Blade Chassis” on page ■...
  • Page 56: Server Module And Component Filler Panels

    A filler panel is a metal or plastic enclosure that does not contain any functioning system hardware or cables. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 57: Install Server Module Filler Panels

    Server Module and Component Filler Panels Do not operate your system with empty slots for more than 60 seconds. Improper cooling and airflow can compromise the operating performance of your system and quickly damage components. For server module and storage drive filler panel installing and removing tasks, see: “Install Server Module Filler Panels”...
  • Page 58: Remove The Server Module Top Cover

    Press down on the server module cover release button and, using the indent for leverage, slide the top cover toward the rear of the server module chassis approximately 0.5 inch (12 mm). Sun Blade X4-2B Service Manual • March, 2014...
  • Page 59: Turning The Locate Indicator On And Off

    Turning the Locate Indicator On and Off Lift the cover straight up from the server module. “Servicing Server Module Components ” on page 63 Next Steps ■ Turning the Locate Indicator On and Off This section provides procedures for turning the Locate indicator on and off remotely (using Oracle ILOM) and locally (using the front panel Locate button), so you can identify the server module within the chassis.
  • Page 60: Web Interface

    The Locater indicator on the Summary screen changes to indicate the status of the Locate indicator. “Set Up for ESD Prevention” on page 54 ■ Next Steps “Remove the Server Module from the Sun Blade Chassis” on page 55 ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 61: Required Tools

    FRU TLI Auto-Update ▼ Turn the Locate Indicator On and Off Locally Once you have identified the server module by its blinking Locate indicator, use this procedure to turn off the indicator. You must be physically present at the server. Before You Begin ■...
  • Page 62 When a server FRU that contains the TLI is removed and a replacement module is installed, the TLI of the replacement module is programmed by Oracle ILOM to contain the same TLI as the other module. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 63: Servicing Server Module Components

    “Servicing the System Battery (CRU)” on page 125 Servicing a Storage Drive (CRU) The Sun Blade X4-2B server module can contain up to four storage drives, which are hot-swappable components. The storage drives are located on the front panel of the server module.
  • Page 64 “Insert Storage Drive Filler Panels” on page 73 ■ Identifying Storage Drives The system software designation for storage drive devices (hard disk drives [HDD] or solid state drives [SSD]) is shown in the following figure. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 65 Identifying Storage Drives Figure Legend Hard disk drive (HDD 0) Hard disk drive (HDD 2) Hard disk drive (HDD 1) Hard disk drive (HDD 3) Related Information: “Identifying Storage Drive Indicators and Mechanical Components” on page 66 ■...
  • Page 66 Service Action Required indicator Power/OK indicator Lever Release button Lever The following topics describe storage drive indicator and mechanical component functions. Ready to Remove Indicator This topic describes the Ready to Remove indicator. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 67 Identifying Storage Drive Indicators and Mechanical Components Function: Blue LED with the following states: ■ On solid: The storage drive is in standby power state. The storage drive can be removed ■ safely during a hot-plug operation. A lit Ready to Remove indicator indicates that service action is allowed on the storage drive.
  • Page 68 ■ “Remove a Storage Drive” on page Drive installation: Use the lever to engage the drive with the internal connector. For ■ more information, see “Install a New Storage Drive” on page Sun Blade X4-2B Service Manual • March, 2014...
  • Page 69 About Disk Backplane Cabling Related Information: “Identifying Storage Drives” on page 64 ■ Storage Drive Failure and RAID A single storage device failure does not cause data loss if the storage devices are configured as a mirrored RAID volume. Failed storage devices, such as HDDs, can be removed, and when a new storage device is inserted, the contents are automatically rebuilt from the rest of the array with no need to reconfigure the RAID parameters.
  • Page 70 Over-temperature condition. Do not operate the server with empty storage device Caution – slots. Always insert a filler panel into an empty storage device slot. See “Insert Storage Drive Filler Panels” on page Sun Blade X4-2B Service Manual • March, 2014...
  • Page 71 About Disk Backplane Cabling “Replace a Storage Drive” on page 72 Next Steps ▼ Install a New Storage Drive Locate the storage drive filler panel in the server module bays. For drive locations on the server, see “Identifying Storage Drives” on page Remove the storage drive filler panel from the server module bays.
  • Page 72 RAID parameters. If the replaced storage device was configured as a hot-spare, the new HDD is automatically configured as a new hot-spare. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 73 About Disk Backplane Cabling ▼ Remove Storage Drive Filler Panels Locate the storage drive filler panel to be removed from the server. Unlatch the storage drive filler panel, and rotate the lever to its fully opened position [1]. Remove the filler panel from the slot by holding the opened release lever and gently sliding the filler panel toward you [2].
  • Page 74: Servicing Dimms (Cru)

    The following topics describe the components of the Fault Remind circuitry: “Fault Remind Button and Charge Status Indicator” on page 74 ■ “DIMM Fault Indicators” on page 75 ■ Fault Remind Button and Charge Status Indicator Sun Blade X4-2B Service Manual • March, 2014...
  • Page 75 DIMM Fault Remind Circuit and ECC Errors The blue Fault Remind button (SW3001) is located on the motherboard next to the Charge Status indicator (CR3002). The Charge Status indicator indicates the usability of the test circuit. When the Fault Remind button is pressed, the Charge Status indicator, lights green to indicate that there is sufficient voltage present in the Fault Remind circuit to activate the fault indicators.
  • Page 76 When the faulty DIMM is replaced and the DIMM fault is cleared using Oracle ILOM, the memory available to the operating system returns to normal. You can use the Oracle ILOM web interface or the command-line interface (CLI) to manually clear faults. For information on how Sun Blade X4-2B Service Manual • March, 2014...
  • Page 77: Identify Faulty Dimms

    DIMM Fault Remind Circuit and ECC Errors to use the Oracle ILOM web interface or the CLI to clear server faults, see the Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation Library at: http://www.oracle.com/goto/ ILOM/docs. Error Correction and Parity The server's processor provides data parity protection on its internal cache memories and error-correction code (ECC) protection.
  • Page 78: Dimm Population Rules And Guidelines

    Install up to four memory channels, with three DIMMs per channel. ■ Install up to 24 DIMMs per server module or up to 12 DIMMs per processor. ■ For optimal performance, install DIMMs in groups of three sockets per channel. ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 79 D2, D5, D8, D11 Black The following illustration shows the motherboard, DIMM slot numbering and DIMM slot ■ locations within the Sun Blade X4-2B enclosure. Detailed Memory Population Rules Rule 1: Always populate the channels as follows. See the following figure. ■...
  • Page 80 A processor with 12 DIMMs. Install processors in all the sockets as shown in the following figure. The following figure shows the DIMM slot designations and population order for the Sun Blade X4-2B. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 81 DIMM Population Rules and Guidelines This is known as the "fill farthest" approach to DIMM installation. Tip – Rule 2: Memory symmetry across processors is required. ■ Processor 1 memory must match processor 0 memory, in placement, type, size, capacity, frequency and voltage.
  • Page 82: Remove Dimms

    This action ejects the DIMM from the slot. Component damage. Exercise caution when removing DIMMs close to the drive Caution – enclosure and P1. Space near the DIMM slot ejector tabs is limited. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 83: Install Dimms

    DIMM Population Rules and Guidelines Carefully lift the DIMM straight up to remove it from the slot. Place the DIMM on an anti static mat. “Install DIMMs” on page 83 Next Steps ■ “Return the Server Module to Operation” on page 127.
  • Page 84: Servicing Usb Flash Sticks (Cru)

    The USB flash drive port 0, P0, might contain the factory-installed Oracle System Assistant USB flash drive. This drive contains server-specific data and provides important server functionality (for more information about Oracle System Assistant, see “Return the Server Module to Operation” on page 127). Sun Blade X4-2B Service Manual • March, 2014...
  • Page 85 Servicing USB Flash Sticks (CRU) Data and functionality loss. USB flash drive P0 (port 0) might contain the Oracle Caution – System Assistant USB flash drive. Do not misplace, damage, or overwrite this drive. Use these procedures to remove and install USB flash sticks: “Remove USB Flash Sticks”...
  • Page 86 Installing a longer USB drive on the rear port might damage the blade when inserted into the chassis. Drives can be no larger than 7.5 mm wide and 43 .0 mm deep. “Return the Server Module to Operation” on page 127. Next Steps ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 87: Servicing A Fabric Expansion Module (Cru)

    Servicing a Fabric Expansion Module (CRU) Servicing a Fabric Expansion Module (CRU) This component is a customer-replaceable unit (CRU). Note – The fabric expansion module (FEM) is available in either single-width or double-width form factor. Figure Legend FEM double-width form factor. FEM single-width form factor.
  • Page 88 Slide the FEM card into the support bracket at a slight angle . Ensure that the edge of the card is under the clips on the bracket. Always install a single-width form factor FEM in FEM 0. Note – Sun Blade X4-2B Service Manual • March, 2014...
  • Page 89: Servicing A Raid Expansion Module (Cru)

    Servicing a RAID Expansion Module (CRU) Press the FEM card carefully into the connector. “Return the Server Module to Operation” on page 127. Next Steps ■ Servicing a RAID Expansion Module (CRU) This component is a customer-replaceable unit (CRU). Note – The RAID expansion module (REM), if ordered, might not arrive installed on the Sun Blade X4-2B.
  • Page 90 ▼ Install a REM Card Use this procedure with the REM removal procedure to replace an existing REM, or use this procedure for first-time installation of a REM card in the server. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 91 Servicing a RAID Expansion Module (CRU) Before You Begin Data loss. Back up your data to an external site before proceeding. The following steps Caution – will remove all data from the system. Prepare the server module for service. “Preparing for Service ” on page Insert a filler panel into the empty server slot to reduce the possibility of a system shut down.
  • Page 92 Linux Sun Blade X4-2B Installation Guide for Linux Operating Systems Oracle Solaris Sun Blade X4-2B Installation Guide for the Oracle Solaris Operating System Windows Sun Blade X4-2B Installation Guide for Windows Operating Systems Sun Blade X4-2B Installation Guide for ESX Software...
  • Page 93 Servicing a RAID Expansion Module (CRU) Remove and retain the three screws securing the REM battery to the card. Remove the REM battery from the REM card. Attach the new battery to the REM card using the three screws. Attach any required battery cables. “Install a REM Card”...
  • Page 94: Servicing Processors (Fru)

    The processors supported by the Sun Blade X4-2B are available in two sizes. The processors with 10 or fewer cores are smaller than the processors with 12 cores. You can determine the size of the processor that you are going to remove and replace in either of these two ways: Use Oracle Integrated Lights Out Manager (ILOM) 3.1 to display processor information.
  • Page 95 Selecting the Correct Processor Removal/Replacement Tool If you choose to visually check the size of the processor, refer to the next two figures to see how to distinguish the smaller processors from the larger processors. The following image shows the smaller processor installed.
  • Page 96 See the following illustration for the Color-Coded Processor Removal/Replacement Tool. Legend Name Green, color-coded removal/replacement tool for the smaller processors—models E5-2609 V2 (4-core), E5-2630 V2 (6-core), E5-2650 V2 (8-core), and E5-2690 V2 (10-core) Sun Blade X4-2B Service Manual • March, 2014...
  • Page 97: Processor Fault Remind Circuit

    Processor Fault Remind Circuit Legend Name Pink, color-coded removal/replacement tool for the larger processor—model E5-2697 V2 (12-core) Component damage. The pink color-coded processor removal/replacement tool must Caution – be used only with the larger processor (the 12-core processor). Likewise, the green color-coded removal/replacement tool must be used only with smaller processors (the 4-, 6-, 8-, and 10-core processors);...
  • Page 98 Processor Fault Remind Circuit The following topics describe the components of the Fault Remind circuitry. Fault Remind Button and Charge Status Indicator Sun Blade X4-2B Service Manual • March, 2014...
  • Page 99 Processor Fault Remind Circuit Do not press the white Clear CMOS Button (SW1801). Note – The blue Fault Remind button (SW3001) is located on the motherboard next to the Charge Status indicator (CR3002). The Charge Status indicator is next to the button and shows the usability of the processor test circuit.
  • Page 100: Identify A Faulty Processor

    Fault Remind button. Related Information: “About the DIMM and Processor Test Circuit ” on page 41 ■ ▼ Identify a Faulty Processor Prepare the server module for service. “Preparing for Service ” on page Sun Blade X4-2B Service Manual • March, 2014...
  • Page 101: Remove A Processor Heat Sink (Fru)

    Processor Fault Remind Circuit Component damage. This procedure requires that you handle components that are Caution – sensitive to static discharge. This sensitivity can cause the component to fail. To avoid damage, ensure that you follow electrostatic discharge safety measures and anti static practices. See “Performing ESD and Anti-static Prevention Measures”...
  • Page 102: Remove A Processor (Fru)

    Processor replacement tool model LGA2011 (green label) is required for this procedure. ■ Component damage. Use the correct processor replacement tool. Attempting to Caution – replace the processor using the incorrect tool could result in irreparable damage to the processor or the motherboard. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 103 Processor Fault Remind Circuit Unpack the processor and processor removal/insertion tool from the replacement processor packaging. Leave the processor in the anti-static tray until it is ready to be installed. Release the two processor pressure frame retaining levers by moving them to their fully open position.
  • Page 104 Processor Fault Remind Circuit Close the right side lever and lift the processor pressure frame up to the fully open position. Push the removal/insertion button on the top of the tool. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 105 Processor Fault Remind Circuit Place the removal/insertion tool on top of the processor. a. Lower the tool into place over the processor socket. b. Ensure that the tool and processor key corners are aligned. c. As required, rotate the tool until the triangle on the side of the tool is facing the front of the server and it is over the left side of the processor socket when viewing the server from the front.
  • Page 106 Click the tab on the removal/insertion tool to secure the tool to the processor. Press the release lever on the tool to release the center button and engage the processor. An audible click indicates that the processor is engaged. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 107 Processor Fault Remind Circuit Lift the processor out of the socket while it is still attached to the removal/insertion tool.
  • Page 108 Processor Fault Remind Circuit Turn the tool upside down and verify that it contains the processor. Hold the processor by its edges and press the center button on the tool to release the processor. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 109: Install A Processor (Fru)

    Processor Fault Remind Circuit Lift the processor out of the tool and place contact side down on an anti-static mat. Clean the thermal compound off the top of the processor using an alcohol wipe. Follow the procedure for the return or the disposal of the processor. “Install a Processor (FRU)”...
  • Page 110 Processor Fault Remind Circuit Push the removal/insertion tool button on the top of the tool. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 111 Processor Fault Remind Circuit Turn the tool upside down, lift the processor by its edges, and place it (circuit side up) in the tool. Ensure that the triangle on the corner of the processor aligns with the triangle on the side of the processor removal/replacement tool.
  • Page 112 When the lever is pressed, the center button releases. An audible click indicates that the processor is locked in place. Ensure that the processor is secure in the tool before rotating the tool. Rotate the tool, so the processor faces downward. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 113 Processor Fault Remind Circuit Properly position the tool over the processor socket and lower it into place. Ensure that the notches on the sides of the processor align with the keys on the socket, and the green triangle on the side of the tool is aligned with the front left corner of the processor socket (when viewing from the front of the server).
  • Page 114: Install A Processor Heat Sink (Fru)

    “Remove a Processor (FRU)” on page 102 Before You Begin ■ “Install a Processor (FRU)” on page 109 ■ Clean the heat sink: Remove any dust or debris that might be lodged in the heat sink fins. ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 115 Processor Fault Remind Circuit Use an alcohol pad to completely clean all thermal compound from the underside of the ■ heat sink. Use the syringe (supplied with the replacement processor) to apply the entire contents (approximately 0.1 ml) of thermal compound as a single dollop to the center of the top of the processor.
  • Page 116 Refer to the “5. Set up Server Module http://www.oracle.com/goto/x86AdminDiag/docs Software and Firmware (Oracle System Assistant)” in Sun Blade X4-2B Installation Guide Setting Up Software and Firmware in Sun Blade X4-2B Installation Guide. “Returning the Server Module to Operation ” on page 127 Next Steps ■...
  • Page 117: Servicing The Motherboard Assembly (Fru)

    Servicing the Motherboard Assembly (FRU) “Getting the Latest Firmware and Software” on page 5 ■ Servicing the Motherboard Assembly (FRU) This component is a field-replaceable unit (FRU). A part designated as a FRU must be Note – replaced by an Oracle-qualified service technician. The motherboard cannot be replaced independently of the server module enclosure.
  • Page 118 Remove any storage drive filler panels from the enclosure and install them on the replacement enclosure. For instructions, see “Remove Storage Drive Filler Panels” on page 73 “Install Server Module Filler Panels” on page 57 Sun Blade X4-2B Service Manual • March, 2014...
  • Page 119 Servicing the Motherboard Assembly (FRU) Remove the internal USB flash sticks from the motherboard and install them on the replacement motherboard. Note the flash drive positions (0 and 1). For instructions, see “Remove USB Flash Sticks” on page Remove the internal FEM card from the motherboard and install it on the replacement motherboard.
  • Page 120 ILM assembly load plate [3]. Be careful not to allow the processor socket cover to fall into the processor socket as Caution – this could result in damage to the socket. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 121 Servicing the Motherboard Assembly (FRU) e. Install a processor into the socket from which you removed the processor socket cover. For instructions for installing a processor, see “Servicing Processors (FRU)” on page 94 “Install a Processor”. f. Repeat Step a through Step e above to remove the second processor socket cover from the replacement motherboard and install the second processor.
  • Page 122 Be careful not to allow the processor socket cover to fall into the processor socket as Caution – this could result in damage to the socket. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 123 Servicing the Motherboard Assembly (FRU) a. Open one of the processor ILM assemblies on the faulty motherboard [Frames 1 and 2]. b. Hold the processor ILM assembly load plate open with one hand and position the processor socket cover over the top of the pressure frame so that 1) the arrow on the processor socket cover is aligned with the arrow on the load plate and 2) the fasteners on one side of the cover...
  • Page 124 To restore FRUID information, log in to Escalation mode. The Escalation mode command-line prompt appears: # Perform the update procedure. “Return the Server Module to Operation” on page 127. Next Steps ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 125: Servicing The System Battery (Cru)

    Servicing the Motherboard Assembly (FRU) ▼ Servicing the System Battery (CRU) This component is a customer-replaceable unit (CRU). Note – A real-time clock (RTC) system battery (type CR2032) is located on the motherboard. The system battery maintains the real-time clock. To remove and replace the system battery: Prepare the server module for service.
  • Page 126 Servicing the Motherboard Assembly (FRU) “Return the Server Module to Operation” on page 127. Next Steps ■ Sun Blade X4-2B Service Manual • March, 2014...
  • Page 127: Returning The Server Module To Operation

    Returning the Server Module to Operation This section describes how to return the Sun Blade X4-2B to operation after you have performed service procedures. Description Link How to prepare the server for operation. “Return the Server Module to Operation” on page 127 How to install the server module cover.
  • Page 128: Install The Server Module Top Cover

    Over-temperature condition. The server module cover must be in place for proper Caution – airflow. Never attempt to run the server module with the cover removed. Equipment damage possible. Hazardous voltage present. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 129: Remove Server Module Filler Panel

    Returning the Server Module to Operation Place the cover on the server module allowing approximately 0.5 inch (12 mm) to extend over the rear of the chassis. Slide the top cover toward the front of the server module chassis until it locks into place. Ensure that you slide the cover under the tabs at the front of the server module.
  • Page 130: Install The Server Module In The Chassis

    To unlock the handles, squeeze the green color lock releases on the end of the handles. Rotate the handles outward, away from the front of the server module. Position the server module vertically so that the ejectors are on the right. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 131: Powering On The Server Module

    Powering On the Server Module Push the server module into the slot until it stops. Ensure that the pawl on the end handle is aligned with the slot on the chassis side wall and rotate both levers inward toward the server module until the locks on the end of the handle click into place.
  • Page 132 Direct the browser using the server module SP IP address. Log in to the server module's Oracle ILOM as a root or a user with administrator privileges. The Oracle ILOM Summary screen appears. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 133 Powering On the Server Module In the Actions section of the Summary screen, verify that the Power State is set to OFF. To power on the server, click Turn On. The server module powers on to full power state and boots. Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation Collection ■...
  • Page 135: Bios Power-On Self-Test (Post) Checkpoints

    BIOS Power-On Self-Test (POST) Checkpoints This section explains POST code checkpoint testing, provides methods to view POST checkpoint codes, lists the POST code checkpoints, and describes how to configure POST code checkpoint options. For information about accessing the BIOS Setup Utility, refer to the Oracle x86 Note –...
  • Page 136: Viewing Post Code Checkpoints

    To view POST checkpoint codes, use Oracle ILOM to reboot the server. “View BIOS POST Code Checkpoints (Oracle ILOM CLI)” on page 137 See Also ■ Oracle Integrated Lights Out Manager (ILOM) 3.1 Documentation Collection ■ (http://www.oracle.com/pls/topic/lookup?ctx=ilom31) Sun Blade X4-2B Service Manual • March, 2014...
  • Page 137: Post Code Checkpoint Reference

    POST Code Checkpoint Reference ▼ View BIOS POST Code Checkpoints (Oracle ILOM CLI) Access a terminal window. To log in to the SP, type: ssh root@SP_IPaddress where SP_IPaddress is the IP address of the server module SP. To start the serial console, type: ->...
  • Page 138: Checkpoint Ranges

    South Bridge initialization before microcode loading 0x05 OEM initialization before microcode loading 0x06 Microcode loading 0x07 AP initialization after microcode loading 0x08 North Bridge initialization after microcode loading 0x09 South Bridge initialization after microcode loading Sun Blade X4-2B Service Manual • March, 2014...
  • Page 139 POST Code Checkpoint Reference Status Code Description 0x0A OEM initialization after microcode loading 0x0B Cache initialization SEC Error Codes 0x0C — 0x0D Reserved for future AMI SEC error codes 0x0E Microcode not found 0x0F Microcode not loaded SEC Beep Codes None Standard Checkpoints: PEI Phase Status Code...
  • Page 140 Memory initialization error. Invalid memory size or memory modules do not match. 0x53 Memory initialization error. No usable memory detected 0x54 Unspecified memory initialization error. 0x55 Memory not installed 0x56 Invalid CPU type or speed. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 141 POST Code Checkpoint Reference Status Code Description 0x57 CPU mismatch 0x58 CPU self test failed or possible CPU cache error 0x59 CPU micro-code is not found or micro-code update is failed 0x5A Internal CPU error 0x5B reset PPI is not available 0x5C-0x5F Reserved for future AMI error codes S3 Resume Progress Codes...
  • Page 142 North Bridge DXE initialization is started 0x6A North Bridge DXE SMM initialization is started 0x6B North Bridge DXE initialization (North Bridge module specific) 0x6C North Bridge DXE initialization (North Bridge module specific) Sun Blade X4-2B Service Manual • March, 2014...
  • Page 143 POST Code Checkpoint Reference Status Code Description 0x6D North Bridge DXE initialization (North Bridge module specific) 0x6E North Bridge DXE initialization (North Bridge module specific) 0x6F North Bridge DXE initialization (North Bridge module specific) 0x70 South Bridge DXE initialization is started 0x71 South Bridge DXE SMM initialization is started 0x72...
  • Page 144 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean-up of NVRAM 0xB7 Configuration Reset (reset of NVRAM settings) 0xB8 - 0xBF Reserved for future AMI codes 0xC0 - 0xCF OEM BDS initialization codes Sun Blade X4-2B Service Manual • March, 2014...
  • Page 145 POST Code Checkpoint Reference Status Code Description DXE Error Codes 0xD0 CPU initialization error 0xD1 North Bridge initialization error 0xD2 South Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4 PCI resource allocation error. Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6...
  • Page 146 OEM SEC initialization after microcode loading 0x1D - 0x2A OEM pre-memory initialization codes 0x3F - 0x4E OEM PEI post memory initialization codes 0x80 - 0x8F OEM DXE initialization codes 0xC0 - 0xCF OEM BDS initialization codes Sun Blade X4-2B Service Manual • March, 2014...
  • Page 147: Bios Setup Utility Menu Options

    BIOS Setup Utility Menu Options This section contains screen shots of the BIOS Setup Utility screens. Following the screenshot for each top level menu is a table of the options available from that menu and sub-menus. “BIOS Main Menu Selections” on page 147 ■...
  • Page 148 Current time is displayed. You can change the time setting. Example: [13:38:27] Active Logical Cores QPI Link Speed (R/O) SLOW, Intel Quick Path Interconnect (QPI) operational speed is displayed. 6.4 GT/s 7.2 GT/s 8.0 GT/s Sun Blade X4-2B Service Manual • March, 2014...
  • Page 149 BIOS Main Menu Selections Main Setup Options Options Defaults Description Total Memory (R/O) Memory in gigabytes is displayed. Example: 16 GB (DDR3) Current Memory Speed Memory speed is displayed. Example: 1333 MHz (R/O) USB Devices (R/O) Detected USB devices are displayed. Example: 1 keyboard, 1 mouse, 3 hubs BMC Status (R/O) BMC Firmware Revision...
  • Page 150 If DIMM is present, memory size in gigabytes is CPU Socket 1 DIMM Information displayed. Otherwise, displays “Not Present. ” D0...D7 See previous DIMM information example. SECURITY SETTING Configure the security setting. Administrator Password Set the Administrator password. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 151 BIOS Main Menu Selections...
  • Page 152 BIOS Main Menu Selections Sun Blade X4-2B Service Manual • March, 2014...
  • Page 153 BIOS Main Menu Selections...
  • Page 154 BIOS Main Menu Selections Sun Blade X4-2B Service Manual • March, 2014...
  • Page 155: Bios Advanced Menu Selections

    BIOS Advanced Menu Selections BIOS Advanced Menu Selections The following screen captures show the BIOS Setup Utility Advanced menu screens. The following table lists the BIOS Setup Utility Advanced menu setup options: Advanced Setup Options Options Defaults Description Processors Enable or disable processor (CPU) features. Hyper-threading Disabled/ Enabled...
  • Page 156 Energy Performance Performance/ Balanced Optimize between performance and power savings. Windows Performance 2008 and later operating systems override this value according Balanced to its power plan. Performance USB PORTS Set USB port configuration parameters. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 157 BIOS Advanced Menu Selections Advanced Setup Options Options Defaults Description EHCI Hand-off Disabled/ Disabled Enable or disable Enhanced Host Controller Interface (EHCI) Enabled hand-off support. Port 60/64 Disabled/ Enabled Enable I/O port 60h/64h emulation support. Enable this setting Emulation Enabled for the complete USB keyboard legacy support for non-USB aware operating systems.
  • Page 158 If TPM Support is disabled, Current TPM Status displays Information (R/O) “TPM SUPPORT OFF. ” If TPM Support is enabled, Current TPM Status displays: TPM Enabled Status: TPM Active Status: TPM Owner Status: Sun Blade X4-2B Service Manual • March, 2014...
  • Page 159 BIOS Advanced Menu Selections Advanced Setup Options Options Defaults Description NETWORK Configure network stack settings. STACK Network Stack Disabled/ Enabled Enable or disable the UEFI network stack. Enabled BMC NETWORK Configure Baseboard Management Controller (BMC) network parameters. BMC Network: Disabled/ Enabled Active management port settings are displayed.
  • Page 160 Current dynamic IPv6 address is displayed. Example: Address 1 – (R/O) fec0:a:8:b7:214:4fff:feca:5f7e/64 Refresh Select Refresh to update to the current settings. IPv6 State (R/O) Disabled/ View whether the IPv6 state is enabled or disabled. Enabled Sun Blade X4-2B Service Manual • March, 2014...
  • Page 161 BIOS Advanced Menu Selections Advanced Setup Options Options Defaults Description Auto IPv6 Disabled/ Disabled Autoconfiguration options are: Configuration Stateless/ Disabled: When autoconfiguration is disabled, only the Link Local address is set. None of the autoconfiguration options to Dhcpv6_ configure an IPv6 address are run. stateless/ Stateless: When enabled, the IPv6 Stateless autoconfiguration Dhcpv6_...
  • Page 162 BIOS Advanced Menu Selections Sun Blade X4-2B Service Manual • March, 2014...
  • Page 163 BIOS Advanced Menu Selections...
  • Page 164 BIOS Advanced Menu Selections Sun Blade X4-2B Service Manual • March, 2014...
  • Page 165: Bios I/O Menu Selections

    BIOS I/O Menu Selections BIOS I/O Menu Selections The following screen captures show the BIOS Setup Utility I/O menu screens.
  • Page 166 Enable or disable Option ROM. If set to enabled, Option ROM Enable Enabled for the card executes as normal. If set to disabled, Option ROM for the card is not copied into memory and the execution of the Option ROM is inhibited. Sun Blade X4-2B Service Manual • March, 2014...
  • Page 167 BIOS I/O Menu Selections I/O Setup Options Options Defaults Description NET2 and NET3 Disabled/ Enabled Enable or disable Option ROM. If set to enabled, Option ROM OpROM Enable Enabled for the card executes as normal. If set to disabled, Option ROM for the card is not copied into memory and the execution of the Note - Ethernet Option ROM is inhibited.
  • Page 168 Use this feature if OS does not support PCI Express and SHPC Resources Padding. hot-plug natively. Legacy iSCSI Configure the iSCSI parameters. Launch Legacy Disabled/ Disabled Enable or disable iSCSI for the add-in card. iSCSI Enabled Sun Blade X4-2B Service Manual • March, 2014...
  • Page 169 BIOS I/O Menu Selections...
  • Page 170 BIOS I/O Menu Selections Sun Blade X4-2B Service Manual • March, 2014...
  • Page 171 BIOS I/O Menu Selections...
  • Page 172 BIOS I/O Menu Selections Sun Blade X4-2B Service Manual • March, 2014...
  • Page 173: Bios Boot Menu Selections

    BIOS Boot Menu Selections BIOS Boot Menu Selections The following screen captures show the BIOS Setup Utility Boot menu screens. The following table lists the BIOS Setup Utility Boot menu setup options: Boot Setup Options Options Defaults Description UEFI/BIOS Legacy BIOS Legacy BIOS Select either Legacy BIOS or UEFI BIOS as the boot mode.
  • Page 174 Boot Set the system boot order. Example: Option [PXE:NET0:IBA XESlot 2000 v2193] Priority [PXE:NET0:IBA XESlot 2001 v2193] [PXE:NET0:IBA XESlot 8800 v2193] [PXE:NET0:IBA XESlot 8801 v2193] [Disabled] Sun Blade X4-2B Service Manual • March, 2014...
  • Page 175: Bios Save And Exit Menu Selections

    BIOS Save and Exit Menu Selections BIOS Save and Exit Menu Selections The following screen capture shows the BIOS Setup Utility Save and Exit menu screen. The following table lists the BIOS Setup Utility Save and Exit menu setup options: Save and Exit Setup Options Description Save Changes and Reset...
  • Page 177: Index

    Index buttons (Continued) locations, 13 anti-static tools, 53 NMI, 17 applying, thermal compound, 115 Power, 16 backing up FRUID information, 117–121, 121–124 Charge Status indicator, 41 battery chassis, 21 REM, 92–93 system, 21 replacing chassis monitoring module (CMM), See CMM REM, 92–93 clearing faults, Oracle ILOM CLI, 133 system, 125–126...
  • Page 178: Sun Blade X4-2B Service Manual • March

    41, 67, 74, 75, 77–78 installing front panel, 13 server module, 57–58 storage drive, 73 Locate, 14, 59–60, 60 removing Power OK, 16, 67 server module, 129–130 Ready to Remove, 15, 66 Sun Blade X4-2B Service Manual • March, 2014...
  • Page 179 Index indicators (Continued) Service Action Required, 15, 67 on-board Fault Remind circuit, 41 storage drives, 66 Oracle ILOM, 23 installing clearing faults CLI, 133 DIMMs, 83–84 CMM, 22 FEM, 88–89 Locate indicator filler panels CLI, 59–60 server module, 57–58 web interface, 60 storage drive, 73 logging in, 43–47 heat sink, 114–117...
  • Page 180 11 installing, 90–92 removing, 55–56 removing, 90 troubleshooting, 29–42 servicing, 89 error correction and parity, 76, 77 removing power, 39–41 DIMMs, 82–83 Service, See Information FEM, 88 Service Action Required, indicator, 67 Sun Blade X4-2B Service Manual • March, 2014...
  • Page 181 Index Service Action Required indicator, 15 tool, processor, 94 service processor, See SP tools, 61 serviceability, components, 26 diagnosing, 36 servicing, 63–126 troubleshooting DIMMs, 74 firmware, 41–42 FEM, 87 server module, 29–42 heat sink, 94 error correction and parity, 76, 77 motherboard assembly, 117–121, 121–124 power, 39–41 preparing for operation, 127–133...

Table of Contents