12 June 1987
6. Unhook the tension spring [A] and take off the old corona wire [B].
7. Clean the endblock, endblock covers, and the corona unit casing with
a blower brush and dry cloth.
8. Hook the corona wire to the front anchor post.
9. Hook the tension spring to the wire; then, hook it to the rear terminal.
(The wire junction [C] should be positioned inside the rear endblock
[D].)
10. Reassemble the charge corona unit.
NOTE:
Make sure that the corona wire [E] is positioned between the
c l e a n e r p a d s [ F ] . A l s o , c h e c k t h e w i r e c l e a n e r m o v e m e n t
using SP 7.
Make sure that the spring that acts upon the home position
sensor actuator is seated correctly.
3-54