8. ADS Operation Checking

When
Purpose
Target
ADS Voltage Checking
Measure
How
Development Bias Voltage Checking
Measure
How
1. Set the ADS reference voltage (SP 56).
2. Adjust the ADS voltage if necessary.
3. Place three sheets of A3/LDG white paper on the exposure glass,
and set SP 57. Then, press the Enter key and the Start key.
4. Write down the "V1" & "K" reading, and set the SP 59. (First set ADS
mode.)
5. Repeat steps 3 through 5 using any original but white paper on the
exposure glass, and confirm that "V1" & "K" (SP 57) and "V1" (SP 59)
all change (SP 57 decrease, SP 59 increase).
: Problem with ADS mode occurs.
: T o c h e c k i f A D S c o n t r o l s d e v e l o p m e n t b i a s v o l t a g e
properly.
: Darker original should increase the development bias
voltage during ADS operation.
: Set SP 57
: A D S v o l t a g e i s d i s p l a y e d o n t h e g u i d a n c e d i s p l a y
("V1"). Also, the number "K", which is the actual ADS
v o l t a g e d i v i d e d b y t h e r e f e r e n c e A D S v o l t a g e ( f i x e d
by SP 56), is displayed.
: SP 59
: A c t u a l b i a s v o l t a g e i s d i s p l a y e d o n t h e g u i d a n c e
display ("V1").
Also,
t h e I D s e n s o r p a t t e r n d e v e l o p m e n t b i a s i s
displayed ("V0").
3-49