Mitsubishi Electric FR-F700PJ Instruction Manual page 80

Air-conditioning inverter
Hide thumbs Also See for FR-F700PJ:
Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
Output current detection signal
166
retention time
Output current detection operation
167
selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
178
STF terminal function selection
179
STR terminal function selection
180
AU terminal function selection
181
RM terminal function selection
182
RH terminal function selection
190
RUN terminal function selection
192
A,B,C terminal function selection
232
Multi-speed setting (speed 8)
233
Multi-speed setting (speed 9)
234
Multi-speed setting (speed 10)
235
Multi-speed setting (speed 11)
236
Multi-speed setting (speed 12)
237
Multi-speed setting (speed 13)
238
Multi-speed setting (speed 14)
239
Multi-speed setting (speed 15)
240
Soft-PWM operation selection
241
Analog input display unit switchover
244
Cooling fan operation selection
245
Rated slip
246
Slip compensation time constant
Constant-power range slip
247
compensation selection
249
Earth (ground) fault detection at start
250
Stop selection
251
Output phase loss protection selection
70
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 10s, 9999
0.1s
0.1s
146
0, 1
1
0
146
0, 10, 9999
1
9999
152
0, 9999
1
9999
152
0 to 5, 7, 8, 10, 12,
14, 16, 24, 25, 60, 62,
1
60
134
64 to 67, 72 9999
0 to 5, 7, 8, 10, 12,
14, 16, 24, 25, 61, 62,
1
61
134
64 to 67, 72, 9999
1
4
134
0 to 5, 7, 8, 10, 12,
1
1
134
14, 16, 24, 25, 62,
64 to 67, 72, 9999
1
2
134
0, 1, 3, 4, 7, 8, 11 to 16,
25, 26, 46 to 48, 57, 64,
70, 79, 90 to 93, 95, 96,
98 to 101, 103, 104,
107, 108, 111 to 116,
1
0
140
125, 126, 146 to 148,
157, 164, 170, 179,
190 to 193, 195, 196,
198, 199, 9999
0, 1, 3, 4, 7, 8, 11 to 16,
25, 26, 46 to 48, 57, 64,
70, 79, 90, 91, 95, 96,
98 to 101, 103, 104,
107, 108, 111 to 116,
1
99
140
125, 126, 146 to 148,
157, 164, 170, 179, 190,
191, 195, 196, 198, 199,
9999
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0, 1
1
1
181
0, 1
1
0
188
0, 1
1
1
264
0 to 50%, 9999
0.01%
9999
95
0.01 to 10s
0.01s
0.5s
95
0, 9999
1
9999
95
0, 1
1
0
172
0 to 100s,
133,
1000 to 1100s,
0.1s
9999
138
8888, 9999
0, 1
1
1
172
Customer
Parameter
Remarks
Setting
166
167
168
Parameter for manufacturer setting. Do not set.
169
170
171
178
179
180
181
182
190
192
232
233
234
235
236
237
238
239
240
241
244
245
246
247
249
250
251
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
GP
GP
GP
IPM
IPM
IPM
MFVC
MFVC
MFVC
06
86
2
07
87
2
0A
8A
2
0B
8B
2
12
92
2
13
93
2
14
94
2
15
95
2
16
96
2
1E
9E
2
20
A0
2
28
A8
2
29
A9
2
2A
AA
2
2B
AB
2
2C
AC
2
2D
AD
2
2E
AE
2
2F
AF
2
30
B0
2
31
B1
2
34
B4
2
35
B5
2
36
B6
2
37
B7
2
39
B9
2
3A
BA
2
3B
BB
2
Parameter list
Parameter
All
Copy
Clear
clear
4

Advertisement

Table of Contents
loading

Table of Contents