2.2
Main circuit terminal specifications
2.2.1
Specification of main circuit terminal
Inverter
Terminal
Terminal Name
Symbol
R/L1,
S/L2,
AC power input
T/L3
U, V, W
Inverter output
P/+, PR
Brake resistor connection
P/+, N/-
Brake unit connection
DC reactor (Filterpack)
P/+, P1
connection
Earth (Ground)
To use Filterpack, connect the R, S, and T cables of Filterpack.
To use Filterpack, remove the jumper across the terminals P/+ and P1, then connect the P and P1 cables of Filterpack.
To use Filterpack, connect the GND cable of Filterpack.
Filterpack
Terminal
Terminal Name
Symbol
R0, S0, T0
Commercial power supply input Connect to the commercial power supply.
Earth (Ground)
Crimping
Terminal
Terminal Name
Symbol
R, S, T
Inverter power supply
P, P1
DC reactor terminal
Inverter earth
GND
(ground) connection
Connect to the commercial power supply.
Do not connect anything to these terminals when using the high power factor
converter (FR-HC2) or power regeneration common converter (FR-CV).
Connect a three-phase squirrel-cage motor or a dedicated IPM motor.
Connect a brake resistor (FR-ABR, MRS type, MYS type) across terminals P/+
and PR.
Connect the brake unit (FR-BU2), power regeneration common converter (FR-
CV) or high power factor converter (FR-HC2).
Remove the jumper across terminals P/+ and P1 and connect a DC reactor.
Do not remove the jumper across terminals P/+ and P1 when neither a
Filterpack nor a DC reactor is connected.
For earthing (grounding) the inverter chassis. Must be earthed (grounded).
For earthing (grounding) the Filterpack.
Must be earthed (grounded).
Cable Color
Black
Connect to R/L1, S/L2, and T/L3 of the inverter.
Remove the jumper across terminals P/+ and P1, and connect to
Red
the terminals P/+ and P1 of the inverter.
Green and yellow
Connect to the earth (ground) terminal of the inverter. (Refer to
stripe
page 18)
Main circuit terminal specifications
Description
Description
Description
Refer
to
page
20
20
34
36
21
23
Refer
to page
2
21
Refer
to page
21
19