Name
Manual controller
DC tach. follower
Three speed selector
Motorized speed setter
Ratio setter
Speed detector
Master controller
Soft starter
Deviation detector
Preamplifier
Pilot generator
Deviation sensor
Frequency setting
potentiometer
Frequency meter (64mm 
60mm)
Calibration resistor

Not available under the IPM motor control.

Rated power consumption.The power supply specifications of the FR series manual controllers and speed controllers are 200VAC 50Hz, 220/220VAC 60Hz,
and 115VAC 60Hz.
Commercially available products
Name
Communication connector
Communication cable
Flathead screwdriver
Blade terminal
Phoenix Contact Co.,Ltd.
Cable Size
2
(mm
)
with insulation sleeve
0.3
0.5
0.75
AI 0,75-10GY
1
1.25, 1.5
0.75 (for two
AI-TWIN 20,75-10GY
cables)
NICHIFU Co.,Ltd.
Blade Terminal Product
2
Cable Size (mm
)
0.3 to 0.75
Contact the manufacturer regarding the delivery schedule, price, specifications, and other information of the products listed here.

A blade terminal with a insulation sleeve compatible with MTW wire which has a thick wire insulation.

Applicable for the terminal ABC.
Model
FR-AX
FR-AL
FR-AT
FR-FK
FR-FH
FR-FP
FR-FG
FR-FC
FR-FD
FR-FA
QVAH-10
YVGC-500W-NS
WA2W 1k
YM206NRI 1mA
RV24YN 10k
(as of Feb. 2012)
Model
Manufacturer
Tyco Electronics
5-554720-3
Corporation
SGLPEV-T
Mitsubishi Cable
(Cat5e/300m)
Industries, Ltd.
24AWG  4
Phoenix Contact Co.,
SZF 0-0,4  25
Blade Terminal Model
without
insulation sleeve
AI 0,5-10WH
AI 0,5-10WH
A 0,75-10
AI 1-10RD
AI 1,5-10BK
A 1,5-10
Number
Product Number
BT 0.75-11
Applications, Specifications, etc.
For independent operation. With frequency meter, frequency
potentiometer and start switch.
For synchronous operation (1.5VA) by external signal (0 to 5V,
0 to 10V DC) 
For three speed switching, among high, middle and low speed
operation (1.5VA) 
For remote operation. Allows operation to be controlled from
several places (5VA)
For ratio operation. The ratios of five inverters can be set (3VA) 
For tracking operation by a pilot generator (PG) signal (3VA) 
Master controller (5VA) for parallel operation of multiple
(maximum 35) inverters.
For soft start and stop. Enables acceleration/deceleration in
parallel operation (3VA)
For continuous speed control operation. Used in combination
with a deviation sensor or synchro (5VA) 
Used as an A/V converter or arithmetic amplifier (3VA) 
For tracking operation. 70V/35VAC 500Hz (at 2500r/min)
For continuous speed control operation (mechanical deviation
detection)
Output 90VAC/90
For frequency setting. Wire-wound 2W 1k type B
characteristic
Dedicated frequency meter (graduated to 120Hz). Moving-coil
type DC ammeter
For frequency meter calibration. Carbon film type B characteristic
Cat.5e cable that is compatible with TIA/EIA standards.
A flathead screwdriver suitable to push the open/close button
Ltd.
for UL wire
----- -
- -----
----- -
AI 0,5-10WH-GB
AI 0,75-10GY-GB
A 1-10
AI 1-10RD/1000GB
AI 1,5-10BK/1000GB
----- -
- -----
Insulation
Blade Terminal
Crimping Tool
VC 0.75
NH 69
Structure, Specifications, etc.
RJ-45 connector
(10BASE-T/100BASE-T/1000BASE-T)
when wiring to the control circuit.
Blade Terminal
Crimping Tool
CRIMPFOX 6
Applicable
Inverter
Applicable for all
models
345