Parameter list
Func-
Parameter
Name
tion
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
Acceleration/deceleration pattern
29
selection
30
Regenerative function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
40
RUN key rotation direction selection
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for reverse
43
rotation
44
Second acceleration/deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
current
51
Second electronic thermal O/L relay
52
DU/PU main display data selection
54
FM terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
60
Energy saving control selection
65
Retry selection
Stall prevention operation reduction
66
starting frequency
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
77
Parameter write selection
78
Reverse rotation prevention selection
 79
Operation mode selection
66
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 400Hz, 9999
0.01Hz
9999
106
0 to 2
1
0
118
131,
0 to 2
1
0
161
0 to 400Hz, 9999
0.01Hz
9999
102
0 to 400Hz, 9999
0.01Hz
9999
102
0 to 400Hz, 9999
0.01Hz
9999
102
0 to 400Hz, 9999
0.01Hz
9999
102
0 to 400Hz, 9999
0.01Hz
9999
102
0 to 400Hz, 9999
0.01Hz
9999
102
0, 0.01 to 9998
0.001
0
150
0, 1
1
0
277
0 to 100%
0.1%
10%
144
0 to 400Hz
0.01Hz
6Hz
144
0 to 400Hz, 9999
0.01Hz
9999
144
0 to 3600s
0.1s
5/15s
113

0 to 3600s, 9999
0.1s
9999
113
0 to 30%, 9999
0.1%
9999
92
0 to 400Hz, 9999
0.01Hz
9999
103
0 to 150%, 9999
0.1%
9999
96
0 to 500A, 9999
0.01A
9999
119
0, 5, 8 to 12, 14, 20,
23 to 25, 50 to 55, 61,
1
0
152
62, 64, 100
1 to 3, 5, 8 to 12, 14, 21,
1
1
152
24, 50, 52, 53, 61, 62
0 to 400Hz
0.01Hz
60Hz
157
Rated
0 to 500A
0.01A
inverter
157
current
0, 0.1 to 5s, 9999
0.1s
9999
161
0 to 60s
0.1s
1s
161
0 to 3
1
0
110
0, 9
1
0
174
0 to 5
1
0
170
0 to 400Hz
0.01Hz
60Hz
96
0 to 10, 101 to 110
1
0
170
0.1 to 600s
0.1s
1s
170
0
1
0
170
0 to 30%
0.1%
0%
131
93,
0, 1, 3, 13, 23, 40, 43,
1
0
123,
50, 53, 120, 210
125,
0 to 15
1
1
181
0, 1, 10, 11
1
1
183
0 to 8
1
1
187
0 to 3, 14 to 17
1
14
193
0 to 2
1
0
196
0 to 2
1
0
197
200,
0 to 4, 6, 7
1
0
213
Customer
Parameter
Remarks
Setting
24
25
26
27
29
30
31
32
33
34
35
36
37
40
41
42
43
44
45
46
47
48
51
52
54
55
56
57
58
59
60
65
66
67
68
69
70
71
72
73
74
75
77
78
 79
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
GP
GP
GP
IPM
IPM
IPM
MFVC
MFVC
MFVC
18
98
0
19
99
0
1A
9A
0
1B
9B
0
1D
9D
0
1E
9E
0
1F
9F
0
20
A0
0
21
A1
0
22
A2
0
23
A3
0
24
A4
0
25
A5
0
28
A8
0
29
A9
0
2A
AA
0
2B
AB
0
2C
AC
0
2D
AD
0
2E
AE
0
2F
AF
0
30
B0
0
33
B3
0
34
B4
0
36
B6
0
37
B7
0
38
B8
0
39
B9
0
3A
BA
0
3B
BB
0
3C
BC
0
41
C1
0
42
C2
0
43
C3
0
44
C4
0
45
C5
0
46
C6
0
47
C7
0
48
C8
0
49
C9
0
4A
CA
0
4B
CB
0
4D
CD
0

4E
CE
0
4F
CF
0

Parameter list
Parameter
All
Copy
Clear
clear
4

Advertisement

Table of Contents
loading

Table of Contents