Rating - Mitsubishi Electric FR-F700PJ Instruction Manual

Air-conditioning inverter
Hide thumbs Also See for FR-F700PJ:
Table of Contents

Advertisement

Rating

7.1

Rating

Three-phase 200V power supply
Model FR-F720PJ-K
Applicable general-purpose motor capacity
(kW)

Rated capacity (kVA)

Rated current (A)
Overload current rating

Rated voltage

Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply
Without Filterpack
capacity (kVA)

With Filterpack
Protective structure (JEM 1030)
Cooling system
Approximate mass(kg)
Model FR-BFP2-K
Approximate mass(kg)
Power factor improving reactor
Common mode choke
EMC filter
Capacitive filter
Protective structure (JEM 1030)
Three-phase 400V power supply
Model FR-F740PJ-K
Applicable general-purpose motor capacity
(kW)

Rated capacity (kVA)

Rated current (A)
Overload current rating

Rated voltage

Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Power supply
Without Filterpack
capacity (kVA)
With Filterpack

Protective structure (JEM 1030)
Cooling system
Approximate mass (kg)
Model FR-BFP2-HK
Approximate mass (kg)
Power factor improving reactor
Common mode choke
EMC filter
Capacitive filter
Protective structure (JEM 1030)

The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor. To use a dedicated IPM motor,
refer to page 339, 340.

The rated output capacity assumes the following output voltages: 220V for the three-phase 200V and 440V for the three-phase 400V class.

The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for
the inverter and motor to return to or below the temperatures under 100% load.

The maximum output voltage does not exceed the power supply voltage.The maximum output voltage can be changed within the setting range. However,
the pulse voltage value of the inverter output side voltage remains unchanged at about

The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).

Open type (IP00) for Filterpack.

The values in parentheses are calculated with 1 fundamental frequency power factor according to the Year 2010 Standard specification for public
constructions (electric installation works), published by the Ministry of Land, Infrastructure, Transport and Tourism in Japan.

The indicated leakage current is equivalent to one-phase of the three-phase three wire
330
Inverter
0.4
0.75
1.5
0.4
0.75
1.5
1.0
1.6
2.7
2.5
4.2
7.0
120% 60s, 150% 0.5s (inverse-time characteristics)
Three-phase 200 to 240V 50Hz/60Hz
1.2
2.1
4.0
0.8
1.2
2.6
Self-cooling
0.8
1.0
1.4
Filterpack
0.4
0.75
1.5
1.3
1.4
2.0
Install the DC reactor in the DC side. 93% to 95% of power supply power factor under 100%
Install a ferrite core on the input side
About 4mA of capacitor leakage current
Inverter
0.4
0.75
1.5
0.4
0.75
1.5
0.9
1.7
2.8
1.2
2.2
3.7
120%60s, 150% 0.5s (inverse-time characteristics)
Three-phase 380 to 480V 50Hz/60Hz
1.1
2.2
4.2
0.7
1.3
2.7
Self-cooling
1.3
1.3
1.4
Filterpack
0.4
0.75
1.5
1.6
1.7
1.9
Install the DC reactor in the DC side. 93% to 95% of power supply power factor under 100%
Install a ferrite core on the input side
About 8mA of capacitor leakage current
2.2
3.7
5.5
2.2
3.7
5.5
3.8
6.3
9.1
10.0
16.5
23.8
Three-phase 200 to 240V
170 to 264V 50Hz/60Hz
±5%
5.0
8.8
12.0
3.4
5.5
8.4
Enclosed type (IP20)

Forced air cooling
1.4
1.8
3.6
2.2
3.7
5.5
2.2
2.8
3.8
load (94.4%

Open type (IP00)
2.2
3.7
5.5
2.2
3.7
5.5
3.8
6.2
9.1
5.0
8.1
12.0
Three-phase 380 to 480V
325 to 528V 50Hz/60Hz
±5%
4.8
8.6
12.0
3.3
5.4
8.5
Enclosed type (IP20)

Forced air cooling
1.5
1.5
3.3
2.2
3.7
5.5
2.3
2.6
4.5
load (94.4%

Open type (IP00)
that of the power supply.
2
connection cable.
7.5
11
15
7.5
11
15
12.1
17.1
22.1
31.8
45
58
17.0
20.0
27.0
11.0
16.0
19.0
3.6
6.5
6.5
7.5
11
15
4.5
6.7
7.0

7.5
11
15
7.5
11
15
12.4
17.5
22.5
16.3
23.0
29.5
17.0
20.0
28.0
11.0
16.0
19.0
3.3
6.0
6.0
7.5
11
15
5.0
7.0
8.2
