(5)
Switching of command source by external signal (X67)
In the Network operation mode, the command source switching signal (X67) can be used to switch the start command
source and speed command source.
 Set "67" to any of Pr. 178 to Pr. 182 (input terminal function selection) to assign the X67 signal to the control terminal.
When the X67 signal is OFF, the start command source and speed command source are control terminal.
X67 Signal State
REMARKS
 The ON/OFF state of the X67 signal is applied only during a stop. It is applied after a stop when the terminal is switched while
the inverter is running.
 When the X67 signal is OFF, a reset via communication is disabled.
NOTE
 Changing the terminal assignment using Pr. 178 to Pr. 182 (input terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr. 59 Remote function selection
Pr. 79 Operation mode selection
Pr. 178 to Pr. 182 (input terminal function selection)
Selection of operation mode and operation location
Start Command Source
No signal
assignment
According to Pr. 338
ON
OFF
Command is valid only from control terminal.
Refer to page 110
Refer to page 200
Refer to page 134
Speed Command
Source
According to Pr. 339
4
217