Error Messages; Descriptive Error; Flow Control - Christie 4K35-RGB Technical Reference

Hide thumbs Also See for 4K35-RGB:
Table of Contents

Advertisement

Error messages

If a command cannot be performed, a descriptive error identifying the problem appears.
For example, the following message indicates a syntax error:
(ITP) - (65535 00000 ERR00005 "ITP: Too Few Parameters")

Descriptive error

The following error codes indicate a problem if a command cannot be performed.
Error code
Description
3
Invalid parameter
4
Too many parameters
5
Too few parameters
6
Channel not found
7
Command not executed
8
Checksum error
9
Unknown request
10
Error receiving serial data
101
Control not found
102
Subcontrol not found
103
Wrong control type
104
Invalid value

Flow control

Normally messages can be sent to the projector before processing of earlier messages is complete—
Christie TruLife+ stores messages in a buffer until ready to process. However, if a series of messages
is sent, Christie TruLife+ may not be able to process them as fast as they arrive and the buffer
becomes full.
If this happens, Christie TruLife+ sends the 13h (Xoff) code to instruct the controller (or any devices
preparing to transmit) to cease transmission. At this point, the controller must respond immediately
and send no more than 10 extra characters or they may be lost (such as, Christie TruLife+ can
accommodate the receipt of up to 10 more bytes after it sends 13h (Xoff)). When the buffer is once
again available, Christie TruLife+ sends a 11h (Xon) command to resume transmission.
Xon and Xoff controls apply to both directions of communication. Christie TruLife+ does not send more
than three characters after it has received a 13h (Xoff) code.
Christie TruLife+ Technical Reference–Serial Commands
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Communicating with Christie TruLife+
Error code
Description
105
Disabled control
106
Invalid language
107
Exceeded list size
110
Communication timeout
111
Communications failure
112
Failed to set hardware
113
Bad file
114
Memory failure
115
Not implemented
116
Invalid security
117
Invalid access group
118
System busy - Try again later
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trulife+

Table of Contents