Water Pump Mechanical Seal Inspection; Water Pump Removal - Honda 2010 CRF250R Service Manual

Table of Contents

Advertisement

COOLING SYSTEM
WATER PUMP
MECHANICAL SEAL INSPECTION
Check the bleed hole of the water pump for signs of
coolant leakage.
If water leaks through
the
bleed hole, replace Ihe
mechanical seal
(page
6-11).
If oil leaks through the bleed hole, replace
the
oil seal
(page
6-11)
A small amount of weeping
from
the bleed hole is
normal.
Make sure that
there
is no continuous coolant
leakage
from the
bleed hole while operating
the
engine.
REMOVAL
Drain the coolant (page 6-7)
Remove the drain bolt and sealing washer.
Remove
the bolts and water pump cover.
Remove
the G-ring and dowel pins.
The
impeller has
Jeft
Loosen the impeller.
hand
threads.
Remove
the right
crankcase cover (page 10-5).
The
impeller has
left
Remove the impeller and plain washer.
hand
threads.
6-10