Show Rmon Alarm-Table - Planet Networking & Communication WSGW-24020 User Manual

24/48-port 10/100/1000mbps with 2/4 shared sfp managed ethernet switch
Table of Contents

Advertisement

startup direction — The alarm that may be sent when this entry is first set to valid. If the first sample (after this entry
becomes valid) is greater than or equal to the rthreshold, and direction is equal to rising or rising-falling, then a single
rising alarm is generated. If the first sample (after this entry becomes valid) is less than or equal to the fthreshold, and
direction is equal to falling or rising-falling, then a single falling alarm is generated.
owner name — Enter a name that specifies who configured this alarm. If unspecified, the name is an empty string.
Default Configuration
The following parameters have the following default values:
type type — If unspecified, the type is absolute.
startup direction — If unspecified, the startup direction is rising-falling.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the following alarm conditions:
Alarm index — 1000
Variable identifier — abc
Sample interval — 360000 seconds
Rising threshold — 1000000
Falling threshold — 1000000
Rising threshold event index — 10
Falling threshold event index — 20
Console (config)# rmon alarm 1000 abc 360000 1000000 1000000 10 20

5.19.6 show rmon alarm-table

The show rmon alarm-table user EXEC command displays the alarms summary table.
Syntax
show rmon alarm-table
Default Configuration
This command has no default configuration.
User's Manual of WGSW-24020/WGSW-48040
-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wsgw-48040

Table of Contents