Z Column Components
Removal
1. Review the information under
2. Open the cable clamp on the left side of the hand-camera assembly.
CAUTION:
Possible equipment damage: Make sure to note to which bracket each cable
attaches. Connecting the cables incorrectly can seriously damage the hand-camera
components.
3. Disconnect the P/J194A and P/J194B connectors from the bottom of the hand-camera assembly
by pressing the tabs on the cables.
1
2
4. Carefully rotate the Z column to access the Z cable side of the column.
5-132
"Preparation" on page
5-1.
1. Cable clamp
2. Z flex cable connector (2X)
C65106