Auto Clean
Auto Clean function.) You can then check the usage count of cleaning cartridges in the
reserved cells or in both the reserved cells and the CAP.
To check the number of times that the cleaning cartridges have been used since they were
loaded into the reserved cells in the library:
1. Press the
2. Press the arrow buttons until the cursor underscores CLEANING INFORMATION.
3. Press the
4. Press the arrow buttons until the cursor underscores EXPORT CARTRIDGE.
5. Press the
all reserved cell cleaning cartridges by domain (or drive type), VOLSER, and usage
count.
Note: If the usage count for a cleaning cartridge has exceeded its warning count,
6. Press the

Exporting Cleaning Cartridges through the CAP

This procedure assumes that cleaning cartridges are loaded into the reserved cells and the
library has been reset. (Taking those two steps enables the Auto Clean function.)
When one or more cleaning cartridges have expired, the customer can export them from
the reserved cells to the CAP with this procedure:
1. Press the
2. Press the arrow buttons until the cursor underscores CLEANING INFORMATION.
3. Press the
The panel displays the Cleaning Info menu.
4. Press the arrow buttons until the cursor underscores EXPORT CARTRIDGE.
5. Press the
The Export Clean Cartridges screen appears, which lists all reserved cell cleaning
cartridges by domain (or drive type), VOLSER, and usage count.
6. Select the cleaning cartridges you want to export by:
a. Moving the cursor to the desired cartridge entry on the list
b. Pressing the
c. Repeating Steps a and b until you have selected all the cartridges you want to
2-52
button to return to the Main Menu.
MENU
button. The panel displays the Cleaning Info menu.
SELECT
button. The Export Clean Cartridges screen appears, which lists
SELECT
the export screen will display EXPIRED. The customer must remove this
cartridge from the library.
button to exit the Export Clean Cartridges screen.
MENU
button to return to the Main Menu.
MENU
button.
SELECT
button.
SELECT
button. A selected cleaning cartridge is then highlighted
SELECT
(in reverse video)