Library Environmental Specifications; Table 1-17. Tape Library Environmental Specifications - StorageTek L700 Service Manual

Tape library and l700-pass-thru port
Hide thumbs Also See for L700:
Table of Contents

Advertisement

Table 1-16. L700/700e Power Cables (Continued)
Input Voltage
Country
200–240 VAC
10 or 15 A
Canada
1.
Notes:
Use locking plugs for DLTs or DLTs mixed with T9x40s.
2.
Europe includes Germany, Norway, Sweden, Denmark, Finland, the Netherlands, Belgium,
France, and Switzerland.

Library Environmental Specifications

Environmental specifications for the library are listed in

Table 1-17. Tape Library Environmental Specifications

Temperature
Operating
Storage
Shipping
Relative Humidity
Operating
Storage
Shipping
Wet Bulb Maximum
Operating
Storage
Shipping
Altitude
Operating
Storage
Shipping
95846
Only T9x40 drives,
newer DLT Drives,
Ultrium Drives, or a
mixture of T9x40
and newer drives
U.S./
NEMA 6–15
10083644
15° to 32°C (59° to 90°F)
10° to 40°C (50° to 104°F)
-40° to 60°C (-40° to 140°F)
20% to 80% (non condensing)
10% to 95% (non condensing)
10% to 95% (non condensing)
29.2°C (84.5°F)
35°C (95°F)
35°C (95°F)
0 to 3.05 km (0 to 10,000 ft)
0 to 3.05 km (0 to 10,000 ft)
0 to 15.24 km (0 to 50,000 ft)
Fourteenth Edition
StorageTek Proprietary
Library Environmental Specifications
If the Library Contains...
Older DLT
Optional Redundant
Drives, (with
non-PFC
power
supplies)
Locking
IEC 60309
410573502
or
provide two Hubbell
NEMA L6–
316R6W receptacles.
15P
10083645
Table
1-17.
AC power option
The customer must