Diagnostic Tests; Get-Put Loop Diagnostic Test - StorageTek L700 Service Manual

Tape library and l700-pass-thru port
Hide thumbs Also See for L700:
Table of Contents

Advertisement

Diagnostic Tests

The Import Clean Cartridges screen appears, which lists all reserved cell cleaning
cartridges by domain (or drive type), and VOLSER.
12. Select the cleaning cartridges you want to import by:
a. Moving the cursor to the desired cartridge entry on the list
b. Pressing the
c. Repeating Steps a and b until you have selected all the cartridges you want to
Note: There is no undo available on this menu. If you select a cartridge by mistake,
13. Press the
Diagnostic Tests
Diagnostic tests simulate online library operation. These tests must be run only when the
target mechanisms are offline. For example, if the test exercises only the robot and does
not affect any drives (as in the Get-Put diagnostic test), only the library must be offline.
If, however, you wish to mount a tape to a drive (Mount-Dismount diagnostic test), both
the library and drive must be offline.
The two tests used to check library and drive operation are the Get-Put Loop and Mount-
Dismount diagnostic tests, which are described in detail below.
CAUTION:
System interruption: If you wish to run tests from a laptop device, you
must connect the laptop to the CSE port on the MPC/MPCL card. Be sure
the library is offline before running tests. The CSE interface does not
give a warning that the library will be taken offline.

Get-Put Loop Diagnostic Test

The Get-Put Loop diagnostic test validates cell-to-cell move capabilities using a
diagnostic cartridge. The robot:
Retrieves (gets) the diagnostic cartridge from its reserved cell
Moves the hand and cartridge laterally and vertically
Places (puts) the cartridge back into the reserved cell
To run the Get-Put Loop diagnostic test:
1. Be sure that the library is offline.
2. Make sure the main access door is closed and the library menu is displayed.
3. Be sure there is a diagnostic cartridge in the reserved area.
2-54
button. A selected cleaning cartridge is then highlighted
SELECT
(in reverse video)
import
you must exit the menu by pressing the
again at Step 10.
button to initiate the import.
SELECT
Fourteenth Edition
StorageTek Proprietary
button. Then you must start
MENU
95846

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

700e