4. From the status screen, press the
5. Using the down arrow button, move the cursor down until it underscores
DIAGNOSTICS.
6. Press
7. Press the arrow button until the cursor underscores GET-PUT Loop.
8. Press
9. Follow the screen directions to set the number of times you wish the test to run.
10. You will be prompted to confirm that you want the library in Maintenance Mode
(offline) before beginning the test (ARE YOU SURE?). Confirm this by pressing
the
11. After this diagnostic test is complete, press
menu.
Mount-Dismount Loop Diagnostic Test
The Mount-Dismount Loop diagnostic test validates the ability of the robot to load and
unload a cartridge to a tape drive. The robot:
•
Retrieves a diagnostic cartridge
•
Loads the tape into a drive
When the drive dismounts the cartridge, the robot:
•
Retrieves the cartridge
•
Places it back into its reserved cell.
To run the Mount-Dismount diagnostic test:
1. Be sure that both the library and target drive are offline.
2. Make sure the main access door is closed and the library menu is displayed.
3. Be sure there is a diagnostic cartridge in the reserved area.
4. From the status screen, press the
5. Press an arrow button until the cursor underscores DIAGNOSTICS.
6. Press the
7. Use the arrow button until the cursor underscores DRIVE DIAGNOSTICS.
8. Press
9. Use the arrow button to move the cursor to the drive you wish to mount.
10. Press the
11. Use the arrow button to move the cursor to MOUNT/DISMOUNT LOOP.
95846
. The panel displays the Main Diagnostic Menu.
SELECT
. The GET-PUT option screen will appear.
SELECT
button.
SELECT
button. The Main Diagnostic Menu screen will appear.
SELECT
. The list of available drives will appear.
SELECT
button. The list of drive diagnostic tests will appear.
SELECT
Fourteenth Edition
StorageTek Proprietary
button on the operator panel.
MENU
to return to the DIAGNOSTICS
MENU
button. The main menu will appear.
MENU
Diagnostic Tests
2-55