  • Page 2: Aim Of This Manual

    AccurioPress C3080/ The machine: Indicates a mechanical part related to the structure or mechanism. C3080P/C3070, AccurioPrint C3070L Microsoft Windows Windows Also, the descriptions use screens from AccurioPress C3080 as examples. The display may be different from AccurioPress C2070/C2060/C2070P and AccurioPrint C2060L.
  • Page 3: Intended Use

    The Daily Maintenance Guide are intended for the following users of this machine: Operator: Person who has been trained by Konica Minolta or authorized partner to operate the system for its intended use as well as manage consumables, and perform the maintenance and troubleshooting described in user's guides.
  • Page 4: Table Of Contents

    Adjustment Order..........................3-4 Adjustment flow to use a new type of paper................3-5 3.4.1 Adjustment timing ..........................3-5 3.4.2 Adjustment sequence .........................3-5 Adjustment Flow when changing the screen ................3-6 3.5.1 Adjustment timing ..........................3-6 3.5.2 Adjustment sequence .........................3-6 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 5: Table Of Contents

    About Exact Color calibration ......................3-83 Executing Exact Color: Color Centro....................3-84 Executing Exact Color: Touch panel....................3-91 3.6.15 About G7 Calibration ........................3-94 Executing G7 Calibration: Color Centro ...................3-95 Executing G7 Calibration: Touch panel ..................3-101 3.6.16 [Package Color Auto Adj.].......................3-103 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 6 Daily Care...
  • Page 7: About Daily Care

    Large Capacity Unit LU-202m / Large Capacity Unit LU-202XL / Large Ca- page 1-15 pacity Unit LU-202XLm Care requirements Alcohol for cleaning Soft cloth Non-woven cloth with no pilling Tips If you have a toner-dedicated vacuum cleaner, you can use it to clean the duplex part. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 8: Cleaning The Duplex Part

    When cleaning, exercise care to prevent any dirt from falling into the paper feed route. Open the front door. Turn ON the main power switch, and turn ON the sub power switch. Lower the lever [M1] counterclockwise. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 9 When cleaning, exercise care not to deform the sheet (A) on the top of the duplex part. When cleaning, exercise care not to touch the transfer roller and the pre-fusing part. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 10 Wipe off stains on the roller of the registration unit using a soft cloth dampened with alcohol (cleaner). Close the cover [M3]. Push the duplex part into the main body, then return the lever [M1] to its original position. Close the front door. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 11: Cleaning Main Body Tray

    If the inside of the main body tray, paper feed roller, or pick-up roller is dirty, follow the steps below to clean them. Open the left side door. Turn ON the main power switch, and turn ON the sub power switch. Pull out Tray 1. Close the left side door. Open the paper feed roller. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 12 When paper is seated properly, close the paper feed roller. If the inside of Tray 1 is dirty, wipe off toner stains using a soft cloth. Return Tray 1 to its original position. Also, clean Tray 2 in the same way. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 13: Cleaning Multi Bypass Tray Mb-506 Or Multi Bypass Tray Mb-508

    If the pick-up roller of Multi Bypass Tray MB-506 or Multi Bypass Tray MB-508 is dirty, wipe off stains using a soft cloth dampened with alcohol (cleaner). When the pick-up roller rotates after one sheet was fed, perform cleaning again. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 14: Cleaning Paper Feed Unit Pf-602M

    Pull out the upper tray. Close the left side door. Clean two paper feed roller using a soft cloth dampened with alcohol (cleaner). Return the upper tray to its original position. Also, clean the lower tray in the same way. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 15 Cleaning Paper Feed Unit PF-602m Open the tray left side door. Open the lever [PF1]. Wipe off stains on the inside using a clean soft cloth. Close the lever [PF1]. Open the lever [PF2]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-10...
  • Page 16 Wipe off stains on the inside using a clean soft cloth. Open the lever [PF3]. Wipe off stains on the inside using a clean soft cloth. Close the lever [PF3] and lever [PF2]. Open the lever [PF5]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-11...
  • Page 17 Cleaning Paper Feed Unit PF-602m Wipe off stains on the inside using a clean soft cloth. Close the lever [PF5]. Close the tray left side door. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-12...
  • Page 18: Cleaning Paper Feed Unit Pf-707 Or Paper Feed Unit Pf-707M

    If the delivery route of Paper Feed Unit PF-707 or Paper Feed Unit PF-707mis dirty, follow the steps below to clean it. Open the tray left side door. Open the lever [PF1]. Wipe off stains on the inside using a clean soft cloth. Close the lever [PF1]. Open the lever [PF2]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-13...
  • Page 19 Wipe off stains on the inside using a clean soft cloth. Close the lever [PF2]. Open the lever [PF4]. Wipe off stains on the inside using a clean soft cloth. Close the lever [PF4]. Close the tray left side door. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-14...
  • Page 20: Cleaning Large Capacity Unit Lu-202M Large Capacity Unit Lu-202Xl, Or Large Capacity Unit Lu-202Xlm

    When the paper feed roller and pick-up roller of Large Capacity Unit LU-202m, Large Capacity Unit LU- 202XL, or Large Capacity Unit LU-202XLm are dirty, wipe off stains using a soft cloth dampened with cleansing alcohol (cleaner). AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-15...
  • Page 21 Cleaning Large Capacity Unit LU-202m, Large Capacity Unit LU-202XL, or Large Capacity Unit LU- 202XLm AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-16...
  • Page 22 Both Sides Adjust...
  • Page 23: What Is Both Sides Adjust?

    Just before a job with important both-side ac- curacy is output • Just before a job with a wide printing area is output • When both-side accuracy is not desirable (you want to increase both-side accuracy) AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 24: Adjustment Flow To Use Paper Of A New Brand, Weight, Or Size

    - With Intelligent Quality Optimizer IQ-501 mounted Adjustment item Reference just- ment order Finely adjust the side guide plates of the paper tray (for PF-707/PF- page 2-7 707m/PF-602m) [AutoMeasure] Adjustment page 2-37 Registering Paper Profile page 2-41 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 25: Regular Adjustment Flow

    - With Intelligent Quality Optimizer IQ-501 mounted Adjustment item Reference just- ment order Finely adjust the side guide plates of the paper tray (for PF-707/PF- page 2-7 707m/PF-602m) [AutoMeasure] Adjustment page 2-37 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 26: Periodical Both Sides Adjustment Function

    For details, refer to page 2-48. Tips When using [Periodical Both Sides Adjustment], manually make the image quality adjustment. mark is printed on the chart to enable you to know from which paper tray the target job is printed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 27: Adjustment Flow For Each Job

    Just before a job with a wide printing area is output When both-side accuracy is not desirable (you want to increase both-side accuracy) 2.4.2 Adjustment Order Adjustment item Reference just- ment order Back Side Fine Adjustment page 2-43 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 28: How To Operate The Both Sides Adj. Item

    If moved only with the front side guide plate, the side guide plates may not be fixed in position. Load paper of the size to be adjusted. % Load about 100 sheets of paper. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 29 NOTICE Be sure not to withdraw the tray till the motor sound stops. Otherwise, the later operation may be af- fected because the bottom plate is not elevated completely to the top. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 30 % Align the stack of paper to the left side of the tray. NOTICE Do not load above the limit level indicated on the side guide plate of the tray. Carefully load paper to be seated under the paper control lever at the air nozzle. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 31: Front] Adjustment

    The paper level indicator of the tray changes from " " to " " on the [MACHINE] screen and [COPY] screen. 2.5.2 [Front] Adjustment Press [Paper Setting] on the [MACHINE] screen. Press the tray in which the paper to be adjusted has been loaded. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-10...
  • Page 32 If the desired paper profile is not found, press [Cancel]. A paper profile, which has "Paper Size" or "Direction" different from that of the paper loaded in the tray, is grayed out, so you cannot select it. Press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-11...
  • Page 33 Make sure that [Front] is selected, then press [Chart Adjustment]. Press [Print Mode]. When the [PRINT MODE] screen is displayed, press Start on the control panel. A test chart is printed. Print approximately three sheets for a test chart. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-12...
  • Page 34 [1], [3], [5], and [7], then proceed to step 12. [2]: 200 mm ^ 0.3 mm [4]: 200 mm ^ 0.3 mm [6]: 200 mm ^ 0.3 mm [8]: 200 mm ^ 0.3 mm AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-13...
  • Page 35 Repeat steps 11 to 14 until the lengths at points [2], [4], [6], and [8] are included in the respective ranges shown below. [2]: 200 mm ^ 0.3 mm [4]: 200 mm ^ 0.3 mm [6]: 200 mm ^ 0.3 mm [8]: 200 mm ^ 0.3 mm AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-14...
  • Page 36: Gap] Adjustment (Back Side Adjustment)

    When the front side adjustment is performed for paper of a new brand, weight, or size, press [Register & OK], then proceed to the next step. 2.5.3 [Gap] Adjustment (Back side adjustment) Press [Paper Setting] on the [MACHINE] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-15...
  • Page 37 How to Operate the Both Sides Adj. Item Press the tray you performed [Front] adjustment for. Press [Change Set]. Press [Both Sides Adj.]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-16...
  • Page 38 Press [Gap], then press [Print Mode]. When the [PRINT MODE] screen is displayed, press Start on the control panel. A test chart is printed. Print approximately three sheets for a test chart. Press [Exit PrintMode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-17...
  • Page 39 1.5 mm. Be sure to make note of the measurement values. Press [a] to [d] of each point, and use the touch panel keypad or [,] / [+] to enter the measured value. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-18...
  • Page 40 A test chart is printed. Print approximately three sheets for a test chart. Check the misalignment of print position using the second and third output charts. Repeat Step 10 to 13 until the front and back are aligned. Press [Exit PrintMode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-19...
  • Page 41: Scan Meas.] Adjustment

    The [Scan Meas.] adjustment is a simple method to adjust only the magnification ratio and image posi- tion of the back side. To make adjustments including the front side, perform [AutoMeasure] adjustment, [Chart Adjustment], or [Zoom]/[Image Shift] adjustment. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-20...
  • Page 42 How to Operate the Both Sides Adj. Item Press [Paper Setting] on the [MACHINE] screen. Press the tray you performed [Front] adjustment for. Press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-21...
  • Page 43 Press [Scan Meas.], and press [Output Background Sheet]. When the [PRINT MODE] screen is displayed, press Start on the control panel. % Output the background sheet for measurement with the paper size of A3 or 11 e 17. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-22...
  • Page 44 Enter the necessary number of adjustment charts, then press Start on the control panel. % You can output 20 or more of the adjustment charts but cannot scan more than 20 sheets for meas- urement. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-23...
  • Page 45 5 cm (2 inches) each from the vertical size guide and horizontal size guide, and align the left and top edges parallel to the vertical size guide and horizontal size guide on the original glass. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-24...
  • Page 46 Chart] screen is added by one, and the blue frame displayed in the illustration on the screen shifts to the next one on the right side. If you move the adjustment chart before the blue frame shifts to the next, the measurement may not be performed properly. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-25...
  • Page 47 % When the screen below is displayed, press [Close] again. % If you press [Return] on the [Scan Adjustment Chart] screen while the scan measurement is in pro- cess, the following dialog is displayed. To stop the scan measurement and discard the measure- AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-26...
  • Page 48 How to Operate the Both Sides Adj. Item ment results obtained so far, press [Yes]. Restart the scan measurement from the first scanning procedure. To continue the scan measurement, press [No]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-27...
  • Page 49 Third time: Set the back side of the adjustment chart face up (turned away from the original glass), with its top edge positioned to the back side. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-28...
  • Page 50 Possible causes to exceed the adjustment range may include that the chart used in the scan meas- urement is incorrect (a different chart has been used), the printing position of the front side has been poorly adjusted, or the adjustments of the reference positions are not completed. Confirm these AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-29...
  • Page 51: Rotate/Skew] Adjustment

    If [User Setting] or [Administrator Setting] - [Common Setting] - [Both Sides Rotate/Skew] in [UTILITY] is set to [Disable], the [Rotate/Skew] adjustment does not function. To perform the [Rotate/Skew] ad- justment, set [Both Sides Rotate/Skew] to [Enable]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-30...
  • Page 52 How to Operate the Both Sides Adj. Item Press [Paper Setting] on the [MACHINE] screen. Press the tray you performed [Front] adjustment for. Press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-31...
  • Page 53 How to Operate the Both Sides Adj. Item Press [Both Sides Adj.]. Press [Rotate/Skew], and press [Chart Adjustment]. Press [Print Mode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-32...
  • Page 54 How to Operate the Both Sides Adj. Item When the [PRINT MODE] screen is displayed, press Start on the control panel. % A test chart is printed. Print approximately three sheets for a test chart. Press [Exit PrintMode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-33...
  • Page 55 2.0 mm in the minus side in the X-axis direction and 1.5 mm in the plus side in the Y-axis direction. % Be sure to make note of the measurement values. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-34...
  • Page 56 [2], [0], and [+/-] in order. Then, select [Y], and press [1] and [5] in order. When the entry is completed, press [Adjustment Start]. % The adjustment values you entered are applied to [Front] and [Back] on the [Rotate/Skew] screen. Press [Chart Adjustment]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-35...
  • Page 57 % A test chart is printed. Print approximately three sheets for a test chart. Check the misalignment of print position using the second and third output charts. % Repeat Step 9 to 14 until the front and back are aligned. Press [Exit PrintMode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-36...
  • Page 58: Automeasure] Adjustment

    On the [MACHINE] screen, press [Adjustment] - [Quality Adj.] - [Periodical Both Sides Adj.] in sequence, and set [Period. Both Sides Auto Adj.] to [ON]. You can then set [Periodical Adjustment] to [ON] or [OFF]. For the tray set to [ON], [Periodical Adjustment] is available. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-37...
  • Page 59 How to Operate the Both Sides Adj. Item Press [Paper Setting] on the [MACHINE] screen. Press the tray in which the paper to be adjusted has been loaded. Press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-38...
  • Page 60 When the [Print Mode] screen is displayed, enter the required number of adjustment charts, and press Start on the control panel. % Up to 20 adjustment charts can be printed out. As the number of charts increases, the accuracy of adjustment values rises. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-39...
  • Page 61 How to Operate the Both Sides Adj. Item Press [Exit PrintMode]. The [AutoMeasure] screen is displayed, and each adjustment value on this screen is updated. % Print out one adjustment chart, and check it. Press [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-40...
  • Page 62: Registering Paper Profile

    If an adjustment is made for paper of a new brand, weight, or size, its contents will be newly registered as a paper profile. Press [Paper Setting] on the [MACHINE] screen. Select a tray, then press [Change Set]. Press [Register & OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-41...
  • Page 63 Enter the paper profile name and press [OK]. Enter the paper brand for the paper profile name. Check that the paper profile name you entered is displayed, then press [Close] to end the registration task. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-42...
  • Page 64: Back Side Fine Adjustment

    Output approximately three sheets of the job data that is actually going to be used from the tray to which "Both Sides Adj." is applied. Press [Paper Setting] on the [MACHINE] screen. Select the tray to which the job data is output, and press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-43...
  • Page 65 How to Operate the Both Sides Adj. Item Press [Both Sides Adj.]. Press [Back]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-44...
  • Page 66 Image magnification adjustment example: When the interval of the image on the front side is set to 400 mm and that of the image on the back side to 401 mm, enter [-0.25%] as the adjustment value. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-45...
  • Page 67 Repeat Step 6 to 8 until the image magnification deviation is cleared. Press [Paper Setting] on the [MACHINE] screen. Select the tray in which the paper to be adjusted has been loaded, then press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-46...
  • Page 68 When the image on the back side is misaligned downward by 0.5 mm and rightward by 0.3 mm against that of the front side, enter [+0.5 mm] in [Up/Down] and [-0.3 mm] in [Right/Left]. The adjustment value is updated in 0.1mm steps. Adjustment range: [Up/Down] -10.0 to +10.0; [Right/Left] -3.0 to +3.0 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-47...
  • Page 69: Periodical Both Sides Adj.]

    Configure settings for the periodical both-side adjustment. This menu item is to be displayed on the machine mounted with Intelligent Quality Optimizer IQ-501. Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. Press [Quality Adjustment] and [Periodical Both Sides Adj.] in sequence. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-48...
  • Page 70 (deviation amount) required to judge that a deviation occurs. The defined value be- tween 0.5 mm and 10.0 mm can be specified. (Default: 2.0 mm) Press [OK]. The screen returns to the [Quality Adjustment Menu] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-49...
  • Page 71 How to Operate the Both Sides Adj. Item AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-50...
  • Page 72: 3 Quality Adj

    Quality Adj.
  • Page 73: Image Controller Ic-605

    Adjustment flow when changing the screen When the screen is changed Reference To not continuously perform the series of adjustment of the image quality adjustment flow, perform page 3-9, and then resume from the next adjustment. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 74: Regular Adjustment Flow (Standard)

    Adjustment item Reference just- ment order Controller Calibration page 3-76 - When an RU optional unit (Relay Unit RU-509/Relay Unit RU-518) is mounted Adjustment item Reference just- ment order Color Density Control setting check page 3-70 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 75: Regular Adjustment Flow (High Accuracy)

    [Paper Setting] - [Color Density Control]. To use general paper, select [Default Adj. Data]. To use special paper or increase the accuracy of the automatic adjustment, [Each Paper Type Color Adj.] is recommended. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 76: Adjustment Flow To Use A New Type Of Paper

    3-103. If you suspend the flow, perform Gamma Automatic Adjustment and then restart the flow. Adjustment 4 is set to Exact Color by default. To switch this adjustment to G7 calibration, contact your service representative. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 77: Adjustment Flow When Changing The Screen

    Adjustment 5 is set to Exact Color by default. To switch this adjustment to G7 calibration, contact your service representative. For "Color Density Control setting check", we recommend that you select [Each Paper Type Color Adj.] to use special paper or increase the accuracy of the automatic adjustment. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 78: Details Of Quality Adjustment Items

    This adjustment (Gamma Automatic Ad- changing the screen justment) Regular adjustment - (None) flow (Standard) Regular adjustment - (None) flow (High Precision) Press Utility/Counter on the machine's control panel. The [UTILITY] screen is displayed. Press [Administrator Setting]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 79 Details of quality adjustment items Press [System Setting]. Press [Expert Adjustment]. Press [Quality Adjustment]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 80: Gamma Automatic Adjustment]

    Image quality adjust- Position of this adjustment ment flow Previous adjustment This adjustment Next adjustment Adjustment flow when Screen selection This adjustment Density Balance Ad- changing the screen justment AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L...
  • Page 81 Maximum Density Ad- flow: High Precision justment On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen. The [Adjustment Menu] is displayed. Press [Execute Adjust Operation] on the [Adjustment Menu] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-10...
  • Page 82: Density Balance Adjustment] (For I1Pro, I1Pro2, Or I1Isisxl)

    For details, refer to page 3-32. A dedicated application is required to measure test charts. The application varies depending on your spec- trophotometer. For i1-Pro, i1-Pro2, or i1iSisXL, use X-rite Measure Tool. Install the tool in advance. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-11...
  • Page 83 On the control panel of the main body, press Utility/Counter. The [UTILITY] screen is displayed. Press [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Density Balance Adjustment] in sequence. Press [Density Balance Chart Output]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-12...
  • Page 84 X-rite Measure tool starts. % The following description uses screen examples in English. To display menus and messages in Eng- lish, select [Language] - [English] on the Measure Tool toolbar, and then restart the X-rite Measure tool. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-13...
  • Page 85 Connect the instrument to the computer. From the menu, click [Device/Port]. The [Instrument Configuration] screen is displayed. In [Instrument], select the spectrophotometer to use. When [OK] is displayed, close the screen. Example: [Eye-One Pro] (i1Pro2) is selected. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-14...
  • Page 86 Specify [Rows] and [Columns], and click [OK]. % When the spectrophotometer is "Type 1" of i1Pro2: [Columns] = 6, [Rows] = 5 % When the spectrophotometer is "Type 2" of i1Pro2: [Columns] = 6, [Rows] = 13 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-15...
  • Page 87 % To eliminate the influence of the color of the table, place 10 sheets of paper of the same type as the chart underneath the chart to be measured. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-16...
  • Page 88 If not measured, an error will occur. When you are finished with the chart measurement, click [Close]. % Continuously, go to "Saving the measured data of the density balance" (page 3-19), and save the measurement data. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-17...
  • Page 89 Select the script data for measurement according to the paper size, and click [Open]. There are some script data items particular for each chart size or type. For details, contact your service representative. On the following screen, click [Start]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-18...
  • Page 90: Saving The Measured Data Of The Density Balance

    Saving the measured data of the density balance You can save the data of the density balance measured with the spectrophotometer to a USB device such as a USB memory stick or to the computer on the network used by the machine. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-19...
  • Page 91 (immediately below) of the USB memory, and specify it as a storage destination. Computer on the net- Open the computer connected to the network used by the machine, and spec- work ify a desired folder. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-20...
  • Page 92: Density Balance Adjustment] (For Fd-5Bt)

    When FD-9 is used as the spectrophotometer, test charts with QR code are printed out. Measuring test charts with QR code allows you to select a definition chart on FD-S2w and automatically input chart numbers and printer information to the machine, thereby, helping ensure efficient input work. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-21...
  • Page 93 Select the chart to be output according to the spectrophotometer to be used. After the selection, press [Print Mode]. The recommended charts are as follows. - [Type 1] of [<Measure Spectrophotometer-1 (FD-9)>] - [Type 3] of [<Measure Spectrophotometer-3 (FD-5 BT)>] AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-22...
  • Page 94 Measuring test charts with QR code allows you to automatically input information such as chart numbers to the machine. Set the paper on the [PRINT MODE] screen and press Start on the control panel. The color chart is output for measurement using the spectrophotometer. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-23...
  • Page 95 Check that the message "Calibration recommended." is displayed on the screen of FD-5BT. % Message appears: Proceed to the next step to perform the white calibration. % No message appears: Proceed to step 11. While [OK] is selected, press the OPTION button. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-24...
  • Page 96 Press FD-5BT on the white calibration plate, and perform the white calibration. When "Calibrating..." is no longer displayed, take the FD-5BT away from the plate. On the computer where FD-S2w has been installed, select [Start] - [All Programs]- [KONICA MINOLTA] - [FD-S2w] - [FD-S2w] in sequence.
  • Page 97 Click [machine name - density balance] and [FD-5 BT / FD-5 BT2], and then click [OK]. Select the chart list according to the type and paper size of the output chart. % Select [Type2] even when you output the Type3 chart. Click [Measurement]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-26...
  • Page 98 % Hold down the side button of FD-5BT. When a "bleep" sounds, slide FD-5BT while holding down the side button. Slide FD-5BT to the bottom side, then release the side button. % For details about how to use FD-5BT, refer to the manual supplied with the spectrophotometer. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-27...
  • Page 99 % Click the alphabet of the row that you measure again when you mistake the row (patch) that you measure. After the measurement, the measurement data is created under the chart list that you used. Right click the measured data, and press [Save]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-28...
  • Page 100 Details of quality adjustment items Enter the 14-digit identification number that is printed to the chart in [PrintID]. Example: 40213150117EBE Enter a filename in [Additional File name]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-29...
  • Page 101 Connect the computer to the same network as the machine, and move on to the next step. Click [Printer], and click [Add]. % If you have added the machine as the destination to save, select the machine from [Printer]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-30...
  • Page 102 % [Printer Name]: Any name % [Password]: Administrator password % [IP Address]: The IP address of the machine % [Port]: 30091 Click [Save]. % When registering measurement data (density balance adjustment value) on the machine, proceed to page 3-32. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-31...
  • Page 103: Registering The Adjusted Value Of The Density Balance In The Machine

    . Registering the measured data saved in the USB memory On the control panel of the main body, press Utility/Counter. The [UTILITY] screen is displayed. Press [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Density Balance Adjustment] in sequence. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-32...
  • Page 104 % If you select the registered number, the adjusted value is overwritten. The following screen is displayed. Connect the USB memory where the measured data has been saved to the main body, and press [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-33...
  • Page 105 On the computer on the network where the measured data has been saved, open a Web browser. % It is recommended that you log in to Web Utilities from the computer where the measured data has been saved. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-34...
  • Page 106 % If the controller of EFI is implemented, ":30091" at the end of the IP address is unnecessary. The main page of the Web Utilities is displayed. Click on [Machine Manager Setting]. Enter the [User Name] and [Password] and click [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-35...
  • Page 107 Click on [ColorMeasuring data Input]. Specify the [File Name] and [File Path] and click [Upload]. % Enter the file name (Example: 2021115011C4CC_i1pro2_2012-10-15.txt). % Click [Browse] of the [File Path] and select the measured data saved in the computer. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-36...
  • Page 108 On the control panel of the main body, press Utility/Counter. The [UTILITY] screen is displayed. Press [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Density Balance Adjustment] in sequence. Press [Density Balance Data Reg/Del]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-37...
  • Page 109 % If you select the registered number, the adjusted value is overwritten. Select the file name of the measured data to be registered and press [OK]. When the following screen is displayed, press [OK]. The adjusted value of the density balance is registered. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-38...
  • Page 110: Density Balance Auto. Adj.]

    Output density balance charts from the machine, and automatically adjust the density balance using Intelli- gent Quality Optimizer IQ-501. Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. Press [Quality Adjustment] and [Density Balance Auto. Adj.] in sequence. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-39...
  • Page 111 Details of quality adjustment items Press [Print Mode]. Press [Quality Adj.]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-40...
  • Page 112 Press [)] on the right side of [Screen Pattern] to display the desired screen. % If necessary, you can press [Screen Pattern] to display the [Screen Pattern] screen and select any screen. Select a screen, and press [OK]. % Press [Close] on the [Quality Adjustment] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-41...
  • Page 113 When Intelligent Quality Optimizer IQ-501 is not provided (with the scanner (Original Glass): Output the density balance chart from the machine to carry out colorimetry using the scanner function. Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-42...
  • Page 114 Details of quality adjustment items Press [Quality Adjustment] and [Density Balance Auto. Adj.] in sequence. Press [Output Chart]. Press [Quality Adj.]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-43...
  • Page 115 Press [)] on the right side of [Screen Pattern] to display the desired screen. % If necessary, you can press [Screen Pattern] to display the [Screen Pattern] screen and select any screen. Select a screen, and press [OK]. % Press [Close] on the [Quality Adjustment] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-44...
  • Page 116 % Take the test chart away from the vertical size guide by 2 inches (5 cm), then push it against the horizontal size guide to load the test chart. % Place about 10 sheets of blank copy paper on the test chart. % Close the ADF. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-45...
  • Page 117 Details of quality adjustment items Press [Start] on the screen. The first scan is carried out. % If an error is detected, the error message shown below is displayed. Referring to the displayed mes- sage, rectify the error. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-46...
  • Page 118 (1) Adjustment value of same screen, same paper type, same weight, and old date (2) Adjustment value of same screen, same paper type, and old date (3) Adjustment value of same screen and old date AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-47...
  • Page 119 [Density Balance Auto. Adjustment Result] is displayed. % If [No] is selected, the adjustment value registration screen below is displayed. Press [Return] to return to the [Density Balance Auto. Adjustment] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-48...
  • Page 120: Maximum Density Adjustment]

    This section describes how to make adjustments when this machine is equipped with Intelligent Quality Op- timizer IQ-501 and Relay Unit RU-509/Relay Unit RU-518. Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. Press [Quality Adjustment] and [Maximum Density Adjustment] in sequence. Press [Print Mode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-49...
  • Page 121: Maximum Density Adjustment] (For I1Pro/I1Pro2)

    You can download the i1Profiler at the following Web site. After installing the tool, restart the computer. i1Profiler (i1Publish) v1.7.1: https://www.xrite.com/service-support/downloads/i/i1profiler-i1publish_v1_7_1 Place the paper for the maximum density management that has been decided in consultation with the service representative. Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-50...
  • Page 122 Select the paper tray loaded with paper for maximum density management, then press Start on the control panel. A chart applied the Screen 1 (Dot190 Recommended) is Output. Press [Exit PrintMode] and return to the [Maximum Density Adjustment] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-51...
  • Page 123 Connect the spectrophotometer to the PC, and wait until [Licensing] turns green. (About 1 minute) % When the registration setting screen appears, select [Register Later]. Select [Advanced] in [User Mode]. Select [i1Pro | i1Pro 2] in [Default display device]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-52...
  • Page 124 Details of quality adjustment items Select [Measure Chart] in [Printer] of Workflow selection. Select [i1Pro] or [i1Pro2] in [Device setup]. Configure [Rows per page] to [5] and [Columns per page] to [4]. Click [Next]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-53...
  • Page 125 Place the spectrophotometer on the patch, and press the button on the spectrophotometer. When you hear a beep sound, check that the read patch is displayed on the screen. For the remeasurement, click the patch that you want to measure again. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-54...
  • Page 126 Details of quality adjustment items % For i1Pro2, install the positioning target to the spectrophotometer before you measure the color. And then, measure K, C, M, and Y of the other patch. When the measurement completes, click [Save Data]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-55...
  • Page 127 In [Custom CGATS Options], configure the settings as shown below, and click [OK]. After you press [OK], 3 text files ("***_M0", "***_M1", and "***_M2") are saved. Open the file with "_M2" at the end of file name among the saved text files in Excel. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-56...
  • Page 128 When two values are same or close, end the adjustment. When two values are extremely different, perform the following adjustment. Acceptable target density range: Y, M, C: from -5% to +5%, K: from -5% to +10% Example: Maximum density target value AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-57...
  • Page 129 Repeat the adjustment from step 25 to step 30 until the maximum density is within the acceptable target density range. Acceptable target density range: Y, M, C: from -5% to +5%, K: from -5% to +10% AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-58...
  • Page 130: Maximum Density Adjustment] (For Fd-5Bt)

    Press [Quality Adjustment] and [Maximum Density Adjustment] in sequence. Press [Print Mode]. Select the paper tray loaded with paper for maximum density management, then press Start on the control panel. A chart applied the Screen 1 (Dot190 Recommended) is Output. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-59...
  • Page 131 Press [Exit PrintMode], and return to the [Maximum Density Adjustment] screen. Connect FD-5BT to the computer, and activate the power of FD-5BT. Use the up down move button on the home screen, and move the cursor to [Sheet] or [Sample]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-60...
  • Page 132 Press the OPTION button and the option screen is displayed. Move the cursor to [Menu] on the option screen, and press the OPTION button. Move the cursor to [Density Options] on the menu screen, and press the OPTION button. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-61...
  • Page 133 % For details about how to use FD-5BT, refer to the manual supplied with the spectrophotometer. Press the return button and the menu screen is displayed. Move the cursor to [Calibration] on the menu screen, and press the OPTION button. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-62...
  • Page 134 Press the return button twice, and the menu screen is displayed. Stack 10 sheets of blank paper for the maximum density management, and place the job that is output in step 5 on top of it. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-63...
  • Page 135 After you move the cursor to [Sample], move the opening of the FD-5BT on the patch that you measure. When you hear a beep sound, the density of the read patch is displayed on the FD-5BT screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-64...
  • Page 136 Input the measurement result in an Excel format. Measure all the maximum density patches of K, C, M, and Y in the same way. Calculate the average of the maximum density for K, C, M, and Y each. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-65...
  • Page 137 Change the adjustment value according to the comparative result of the calculated value and the max- imum density target value. % The change value of density differs according to the paper. Reference: The change value of density for POD gloss coat 128g/m -Y: Δ0.006/step -M: Δ0.01/step -C: Δ0.013/step -K: Δ0.01/step AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-66...
  • Page 138: Max. Density Auto Adj.]

    For details, contact your service representative. When Intelligent Quality Optimizer IQ-501 is mounted, [Maximum Density Auto Adjustment] is dis- played. When Intelligent Quality Optimizer IQ-501 is not mounted, [Max. Density Auto Adj. (RU)] is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-67...
  • Page 139 Press [Quality Adjustment] and [Max. Density Auto Adj. (RU)] in sequence. Press [Print Mode]. Load paper used to register a desired density in a tray. The paper profile for the tray automatically changes to the one used for registering a desired density. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-68...
  • Page 140 Note that the paper profile for the tray remains in the one used for registering a desired density. % When you want to make fine-adjustment after checking the result of the automatic adjustment, manually make adjustments using the Maximum Density Adjustment in the section above. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-69...
  • Page 141: Checking The Color Density Control Setting

    [Use Color Density Control] to [ON]. On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen. The [Adjustment Menu] is displayed. Press [Quality Adjustment] on the [Adjustment Menu]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-70...
  • Page 142 Details of quality adjustment items Press [Color Density Control]. Press [Basic Setting]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-71...
  • Page 143 This function adjusts both the primary colors (CMYK) and secondary colors (RGB). % To reduce the paper consumption for color density control: [Standard] This function only adjusts the primary colors (CMYK). When Intelligent Quality Optimizer IQ-501 is mounted on the machine, [Precise] is always set. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-72...
  • Page 144: Color Density Manual Control]

    [Color Density Manual Control] You can manually adjust the color density. On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen. The [Adjustment Menu] is displayed. Press [Quality Adjustment] on the [Adjustment Menu]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-73...
  • Page 145 Details of quality adjustment items Press [Color Density Control]. Press the [Color Density Manual Control] of [Expert Setting]. Press [Print Mode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-74...
  • Page 146 After selecting the tray on the PRINT MODE screen, press Start on the control panel. % To set the output tray, press [Output Setting] at the upper right of the PRINT MODE screen. When the chart is output, the manual control is completed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-75...
  • Page 147: About Controller Calibration

    To reproduce stable colors, make other image quality adjustments as necessary, such as when chang- ing screens or papers or when hue is important. For details, refer to page 3-6, page 3-3, and page 3-4. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-76...
  • Page 148: Executing Calibration

    Check that the instrument to be used is displayed under [Calibration]. % If the correct instrument is not displayed, select the instrument to be used from the menu bar [Set- tings] - [Instrument]. Example: Check that [Instrument: i1Pro2(M0)] is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-77...
  • Page 149 Example: Set the [Paper Type] to [Coated GL], and the [Screen Settings] to [Screen 1] (default). Item Setting [Paper Type] [Coated GL] [Screen Settings] [Screen 1] • You do not need to change from the default set- ting, [Screen 1]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-78...
  • Page 150 Click [Print]. Print the color chart that is to be measured using the instrument. The [Print Chart] screen is displayed. On the [Print Chart] screen, set the [Copies] and [Paper Tray]. After setting, click [Print]. Example: AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-79...
  • Page 151 Tray 1 A test chart is printed. On the chart, Print Date, Output Number of Sets, and No. are printed. Connect the instrument to the computer and click [Start] on the [Execute Calibration] screen. Calibration starts. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-80...
  • Page 152 % To eliminate the influence of the color of the table, place 10 sheets of paper of the same type as the chart underneath the chart to be measured. When the following message is displayed, click [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-81...
  • Page 153 When the chart measurement is completed, the measurement result is displayed at the bottom of the [Execute Calibration] screen. Check the measurement result. If there is no problem, register the calibration table. % By registering the acquired calibration data in the image controller, this data can be applied when printing. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-82...
  • Page 154: About Exact Color Calibration

    (Exact Color) wizard as necessary. The following two methods are available to perform Exact Color. Manual adjustment by using Color Centro Automatic adjustment by using the touch panel . Meaning and Purpose of Advanced Controller Calibration (Exact Color) AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-83...
  • Page 155: Executing Exact Color: Color Centro

    % The device driver for the instrument must be installed on your computer beforehand. For details, refer to the instrument's manual. Start Color Centro and log in to the machine. The Color Centro top screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-84...
  • Page 156 Click [Settings] under [1. Paper Type/Screen Settings]. Set the [Paper Type] and [Screen Settings] on the [Paper Type/Screen Settings] screen and click [OK]. Example: Set the [Paper Type] to [Coated GL], and the [Screen Settings] to [Screen 1] (default). AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-85...
  • Page 157 [Screen Settings] [Screen 1] • You do not need to change from the default set- ting, [Screen 1]. Click [Start Calibration]. % To enable this button, disable Color Density Control. The [Execute Calibration] screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-86...
  • Page 158 Click [Execute Wizard of Exact Color] under [3. Exact Color]. The wizard for executing the Exact Color function starts and displays the [Operation steps] screen. On the [Operation steps] screen, click [Next]. The [1. Create of current table(ExCol)] screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-87...
  • Page 159 Details of quality adjustment items Click [Print]. Print the color chart that is to be measured using the instrument. A test chart is printed. Click [Start]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-88...
  • Page 160 Example: Measurement is performed using i1Pro2. After the message, [Calculating] is displayed, the [Operation steps] screen is displayed. On the [Operation steps] screen, click [Next]. The [2. Accuracy Measurement(ExCol) Enhancement of a correction table(FB1)] screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-89...
  • Page 161 Print the color chart that is to be measured using the instrument. A test chart is printed. Click [Start]. Measure the chart using the instrument. After you finish the chart measurement, click [Next]. The [Operation steps] screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-90...
  • Page 162: Executing Exact Color: Touch Panel

    % By registering the acquired calibration data in the image controller, this data can be applied when printing. Click [Yes] on the [Information] screen. The calibration table is registered in the image controller. Executing Exact Color: Touch panel To use this function, mount Intelligent Quality Optimizer IQ-501 on the machine. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-91...
  • Page 163 Details of quality adjustment items Press [Controller]. Press [Color Management]. Press [Exact Color]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-92...
  • Page 164 Selecting [Custom Screen] displays the Custom Screen Setting. Press [Execute]. [Controller] flashes red during execution. A chart is printed up to 5 times. When processing is completed, a message is displayed. Press [Close]. The result is displayed. Press [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-93...
  • Page 165: About G7 Calibration

    * The sample screen may be different from the actual display depending on your system environment and application version/revision. .Workflow Loading and Registering the Paper (Coated GL) a Performing G7 Calibration: Color Centro (page 3-95) b Performing G7 Calibration: Touch panel (page 3-101) AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-94...
  • Page 166: Executing G7 Calibration: Color Centro

    Check that the instrument to be used is displayed under [Calibration]. % If the correct instrument is not displayed, select the instrument to be used from the menu bar [Set- tings] - [Instrument]. Example: Check that [Instrument: i1Pro2(M1)] is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-95...
  • Page 167 Example: Set the [Paper Type] to [Coated GL], and the [Screen Settings] to [Screen 1] (default). Item Setting [Paper Type] [Coated GL] [Screen Settings] [Screen 1] • You do not need to change from the default set- ting, [Screen 1]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-96...
  • Page 168 Details of quality adjustment items Click [Start G7 Calibration] under [3. G7 Calibration]. The [Start G7 Calibration] screen is displayed. Click [Print]. Print the color chart that is to be measured using the instrument. A test chart is printed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-97...
  • Page 169 Example: Measurement is performed using i1Pro2. % By registering the acquired calibration data in the image controller, this data can be applied when printing. Click [OK] on the [Information] screen. The calibration table is registered in the image controller. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-98...
  • Page 170 On the [Calibration Manager] screen, click [Accuracy Measurement] under [3. G7 Calibration]. The [Accuracy Measurement of G7Calibration] screen is displayed. Click [Print]. Print the color chart that is to be measured using the instrument. A test chart is printed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-99...
  • Page 171 Gray Step (gray balance) are displayed. -[CMYK Density]: Check whether the [D-Max] (maximum density) under [Measure] is in its appropriate range. Check whether the [Target] and [Density (after Calibration)] in the graph are close. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-100...
  • Page 172: Executing G7 Calibration: Touch Panel

    Based on the [Gray Balance], [Delta-L*], [Δa*], [Δb*], and [ΔCh] values, check the gray reproducibility. % When [Report Print] is clicked, the measurement results for G7 calibration is printed. Executing G7 Calibration: Touch panel To use this function, mount Intelligent Quality Optimizer IQ-501 on the machine. Press [Controller]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-101...
  • Page 173 Details of quality adjustment items Press [Color Management]. Press [G7 Calibration]. Press [Change] in [Paper Tray Setting], and select a tray. To appropriately print charts, select a tray in which the appropriate size of paper is loaded. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-102...
  • Page 174: Package Color Auto Adj.]

    Automatically adjust colors collectively. This menu item is to be displayed on the machine mounted with In- telligent Quality Optimizer IQ-501. Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. Press [Quality Adjustment] and [Package Color Auto Adj.] in sequence. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-103...
  • Page 175 Before making adjustments, you can press [Initial Set.] to change adjustment settings as needed. Change any setting ([Screen of Adjustment Target], [Additional Adjustment], [Maximum Density Adjust- ment Tray], or [Adjustment Tray]). % You can press [Previous] or [Next] to move the page. Press [Start]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-104...
  • Page 176 Details of quality adjustment items When the adjustment is completed, the adjustment result is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-105...