23.2.1

P-5: IDC Sensor (Front) failure

23.2.2
P-28 IDC Sensor (Back) failure
IDC / Registration Sensor /1 (SE1)
IDC / Registration Sensor /2 (SE2)
Step
1
Wipe clean the surface of the Transfer Belt with a soft cloth, if it is dirty
2
Change the Image Transfer Belt Unit if the Transfer Belt is damaged.
3
Reinstall or reconnect SE1 or SE2 if it is installed or connected improperly.
4
Clean SE1 or SE2 if it is dirty
5
Check the HV1 connector for proper connection and correct as necessary.
Open and close the Front Door, run an image stabilization sequence, and select
[State Confirmation] → [Level History 1] to check the IDC value.
6
IDC1: SE1, IDC2: SE2
If the value is 1.0 V or less, change SE1 or SE2.
7
Change PWB-M