Level History2; Temp. & Humidity; Memory/Hdd Adj - Konica Minolta bizhub C250P Service Manual

Hide thumbs Also See for bizhub C250P:
Table of Contents

Advertisement

17. Jig Soft
17.13.4

Level History2

Functions
• IDC Sensor (Transfer Belt bare surface level) as adjusted through the image stabili-
zation sequence and ATVC value.
Use
• Used for troubleshooting of image problems.
Setting/
• IDC Sensor: Shows the intensity adjustment value (0 to 255) of the IDC Sensor.
Procedure
• ATVC (C, M, Y, K): Shows the first image transfer ATVC adjustment value
• ATVC (2nd)
17.13.5
Temp. & Humidity
Functions
• To display the temperature and humidity of a specific location (AIDC Sensor portion)
inside the machine and fusing temperature.
Use
• Used as reference information when a malfunction occurs.
Setting/
• Temp-Inside
Procedure
• Temp-Heater
• Temp-press.
• Humidity
• Absolute Humidity
17.13.6

Memory/HDD Adj.

A. Memory Check
Functions
• To check correspondence of data written to and that read from memory through
write/read check.
Rough Check
• A check is made to see if the image data reading and writing are correctly made in a
very limited area.
• The progress of the check sequence is displayed in percentage.
Detail Check
• A check is made to see if the image data reading and writing are correctly made at
the addresses and buses in all areas.
• The progress of the check sequence is displayed in percentage.
Use
• If the print image is faulty.
Adjustment
1. Call the Service Mode to the screen.
2. Click these keys in this order: [State Confirmation] → [Memory / HDD Adj.] → [Mem-
Procedure
ory Check].
3. Select the desired type of check, either Rough Check or Detail Check.
4. Press the Start key to start the check procedure.
5. When the check procedure is completed, the results are shown on the screen.
If the check results are NG, check the memory for connection or replace the memory
with a new one.
✽ Press the Stop key to interrupt the check sequence.
266
(300 V to 3000 V).
: Shows the second image transfer ATVC adjustment value
(300 V to 5000 V).
: 0 to 100 °C in 1 °C increments
: 0 to 255 °C in 1 °C increments
: 0 to 255 °C in 1 °C increments
: 0 to 100 % in 1 % increments
: 0 to 100 in 1 increments
Field Service Ver. 2.0 Mar. 2006