11. Other
[6]
[5]
11.3.27

Right Door Assy

[1]
[2]
108
[5]
[7]
[6]
4038F2C127DA
4038F2C153DA
4038F2C154DA
Field Service Ver. 2.0 Mar. 2006
5. Remove four Screws [5] and two
Claws [6], and remove the Hopper
Drive Assy [7].
1. Remove the PWB Box.
See P.111
2. Remove the High Voltage Unit.
See P.92
3. Remove the Upper Rear Cover.
See P.74
4. Remove the Harness from the Edge
Cover [1].
5. Remove the Harness from the Wire
Saddle [2].