List of the CS Remote Care error code

A. When Connecting by Modem
Error code
1
0001
The line is busy (Busy detection)
0002
Failure of the Modem default setting at transmit-
ting (When the transmission completes with
modem initial setting failed)
0003
Timeout of CONNECT at transmitting
(No response to ATD)
0005
Timeout of CONNECT at receiving
(No response to ATA)
0006
Shut down of the data modem line (Host)
(Carrier OFF is detected)
0008
Timeout of start request telegram delivery
(Start request telegram is not delivered after line
connection)
0009
Timeout of finish request telegram delivery
(Finish request telegram is not delivered (Start of
shut down).)
000A
Receiving rejection
(Receiving is made when the main unit is set to
reject receiving.)
000B
RS232C Driver Over Run
(When the modem detects Over Run.)
000C
If the same error is detected several times, turn
the modem power OFF and ON.
000D
Break Interrupt (BI) Indicator
(When the modem detects Break Interrupt (BI)
Indicator.)
0011
Baud Rate ERROR
(When selected Baud Rate is out of the specifica-
tion (9600 bps to 38400 bps).)
0018
Machine ID has already been registered
(Request telegram 2 (SET-UP) comes from the
main unit that has already registered Machine
ID.)
0019
Center ID Error
(Center ID of the host is not identical with the one
of start request telegram.)
244
Error
Field Service Ver. 2.0 Mar. 2006
Solution
• Transmit again manually.
• Check if the power of the
modem is ON.
• Check the connecting condition
between the modem and the
main unit.
• Transmit again manually
• Check if the power of the
modem is ON.
• Check the connecting condition
between the modem and the
main unit.
• Check if the power of the
modem is ON.
• Check the connecting condition
between the modem and the
main unit.
• No solution, because the line is
shut down at the host side.
• Transmit again manually.
• Transmit again manually.
• Check the setting condition of
the host side.
• Check the setting condition of
the main unit side.
• If the same error is detected
several times, turn the modem
power OFF and ON.
• If the same error is detected
several times, turn the modem
power OFF and ON.
• If the same error is detected
several times, turn the modem
power OFF and ON.
• Check the Baud rate of the
software DipSW.
• Set the initial registrations
again for all including the host
side.
• Check Center ID setting of the
main unit side.
• Check Center ID setting of the
main unit side.