Software Sw Setting For Cs Remote Care - Konica Minolta bizhub C250P Service Manual

Hide thumbs Also See for bizhub C250P:
Table of Contents

Advertisement

Field Service Ver. 2.0 Mar. 2006
17.8.3

Software SW setting for CS Remote Care

NOTE
• SW bits data are written into the NVRAM every time a change is made. In case you
changed bit data by accident, be sure to restore the previous state.
A. Input procedure
1. Select [Service Mode] → [CS Remote Care] → [Detail Setting], and click [Software
Switch Setting].
2. Click [Switch No.], and input the SW number (two digits) using the 10-Key Pad.
3. Click [Bit Assignment], and select SW bit number using the arrow keys, and input 0 or 1
using the 10-Key Pad.
(For setting by hexadecimal numbers, click [HEX Assignment] key, and input using the
10-Key Pad or A to F keys.)
4. Click [Fix].
NOTE
• About functions of each switch, see to "B. List of software SW for CS Remote
Care."
B. List of software SW for CS Remote Care
NOTE
• Do not change any bit not described on this table.
SW No.
Bit
SW 01
0
Dial Mode
1
Reservation
2
Reservation
3
Reservation
4
Baud rate
5
6
7
SW 02
0
Emergency transmission
1
Auto call on date specification
2
Reservation
3
Reservation
4
Reservation
5
Auto call on the IC Life
Auto call on CCD Clamp/Gain
6
Adjustment failure
7
Reservation
SW 03
0
Reservation
1
Auto call on the toner empty
2
Reservation
3
Auto call on the waste toner bottle full
4 to 7 Reservation
SW 04
0 to 7 Reservation
Functions
17. Jig Soft
0
1
Pulse
Tone
*1
*1
*1
*1
*1
*1
*1
*1
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Do not call
Call
Default
1
0
0
0
0
0
0
1
1
1
0
0
0
1
1
0
0
1
0
1
0
0
233

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents