16. TECH. REP. MODE
(3) Send Setting
<SMTP server>
1
Functions
• To set the SMTP sever address for transmission used for the CS Remote Care.
Use
• To set the SMTP server address
Setting/
<Input IP Address>
Procedure
• IP Address Version 4 format
[0 to 255].[0 to 255].[0 to 255].[0 to 255]
<SMTP port number>
Functions
• To set the SMTP port number for transmission used for the CS Remote Care.
Use
• To set the Port Number of the SMTP Server.
Setting/
• The default setting is 25.
Procedure
<SMTP Connect Timeout>
Functions
• To set the timeout period for transmission.
Use
• To change the timeout period for connection during transmission.
Setting/
• The default setting is 60 Sec.
Procedure
<Auth. Setting>
1
Functions
• To set whether or not to authenticate during transmission via SMTP server.
Use
• To use when authenticating during transmission.
Available authentication mode: POP Before SMTP, SMTP
Setting/
• The default setting is OFF.
Procedure
* Setting to "POP Before SMTP" will set the time for POP Before SMTP.
• The default setting is 60 Sec.
(4) TX/RX Test
Functions
• To determine the correct transmission and reception using CS Remote Care.
Use
• Use to determine the correct transmission and reception using CS Remote Care.
Setting/
• Press the Start key to let the machine start the transmission and reception test.
Procedure
• The test procedure and result will be displayed on the screen.
(5) Data Initialize
Functions
• To initialize the contents for the sever setting.
Use
• Use to initialize the contents for the server setting.
Setting/
• The default setting is No.
Procedure
208
"60 Sec" (30 to 300 Sec)
"OFF"
POP Before SMTP
"60 Sec" (0 to 60 Sec)
Yes