Ph Unit - Konica Minolta bizhub C250P Service Manual

Hide thumbs Also See for bizhub C250P:
Table of Contents

Advertisement

Field Service Ver. 2.0 Mar. 2006
11.3.24

PH Unit

A. Removal Procedure
1. Remove the Front Cover.
See P.81
2. Remove the Image Transfer Belt Unit.
See P.32
[1]
[2]
[4]
[5]
[6]
[3]
4038F2C106DA
4038F2C107DA
[7]
4038F2C108DB
3. Remove the Screw [1] and discon-
nect the Connector [2] respectively,
and remove three Imaging Unit
Guide rails [3].
4. Disconnect the Flat Cable [4] and the
Connector [5] of the PH Unit (Black).
5. Unhook the tab [6], and remove the
Gear [7] of the PH Unit (Black).