Ce001: Abnormal Message Queue; Ce003: Task Error; Ce004: Event Error; Ce005: Memory Access Error - Konica Minolta bizhub C250P Service Manual

Hide thumbs Also See for bizhub C250P:
Table of Contents

Advertisement

Field Service Ver. 2.0 Mar. 2006
23.5.92

CE001: Abnormal message queue

23.5.93

CE003: Task error

23.5.94

CE004: Event error

23.5.95

CE005: Memory access error

23.5.96

CE006: Header access error

23.5.97

CE007: DIMM initialize error

MFP Control Board (PWB-MFP)
Step
1
Check the connectors on PWB-MFP for proper connection and correct as necessary.
2
Change PWB-MFP.
23.5.98

CE002: Message and Method parameter failure

1
MFP Control Board (PWB-MFP)
Step
If it occurred after upgrading the Firmware, conduct the following setting.
[Tech. Rep. Mode] → [Version Upgrad] → [HDD Ver. Upgrad]
1
See P.189
Turn OFF the main power switch and turn it ON again, and conduct the following setting.
[Tech. Rep. Mode] → [Initialization] → [Data Clear].
2
See P.188
3
Format Hard Disk.
4
Change Hard Disk.
5
Change PWB-MFPC.
23.5.99

CEEE1: MSC undefined malfunction occurring

MFP Control Board (PWB-MFP)
Step
1
Check the connectors on PWB-MFP for proper connection and correct as necessary.
2
Change PWB-MFP

23.5.100 CEEE3: Engine Section undefined malfunction

Mechanical Control Board (PWB-M)
Step
1
Check the PWB-M connector for proper connection and correct as necessary.
2
Change PWB-M
Relevant Electrical Parts
Action
Relevant Electrical Parts
Hard Disk
Action
Relevant Electrical Parts
Action
Relevant Electrical Parts
Action
23. Malfunction code