IMI66–109, Section Five

Programming The OAI Number And Master Channel

The master channel refers to a DXP digital station port that you have reserved for call processing control.
After signing into the technician access level, select the system-setup option. Hold down the ALT key and
1.
press the Y key or highlight system-setup and press ENTER. The system-setup options will open. See Figure
5-5 for details.
2.
Select the QuickQ master setup. Hold down the
ALT key and press the M key or press the
ENTER key with QuickQ master setup
highlighted. Enter the intercom number of an
unassigned DXP digital station port, then press
the ENTER key. For the Master 2 extension, enter
the intercom number of a second unassigned DXP
digital station port. The cursor will advance to the
OAI code option. Select the OAI code to use for
QuickQ (01—64). The number that you use here
5 – 4 Setting Up The Personal Computer

Figure 5-5. Viewing The System-Setup Window

Setting Up The Personal Computer
must match the number that you assigned to the
agent and supervisor's telephone in station class of
service button mapping.
3.
To save the changes, press and hold the ALT key
and press the S key. The save changes? window
will open with a Yes No option.
To select the yes option, use the TAB key or the
4.
left arrow key to highlight yes and press the
ENTER key.