DXP Plus Main Common Equipment Cabinet
1.0 Installing The Common Equipment Cabinet
1.1
Considering The Mounting Parameters
Choose a suitable location.
A suitable location is within four feet of a proper electrical outlet. (The main cabinet and two expansion
cabinets requires two dedicated 117VAC 15 AMP circuits, with a third-wire ground, supplied to standard
NEMA 5-15R electrical outlets. Each outlet must be supplied from the opposite phase of the AC power line.
A suitable location provides a distance between the common equipment and the TELCO/PBX jacks of 25
feet or less as per FCC requirements. (Good engineering practices recommend a nominal distance of 7 feet.)
A suitable location allows enough room between the top and bottom of the main cabinet and the ceiling or
floor of the equipment room for placement of one expansion cabinet above and one expansion
cabinet below the main cabinet.
A suitable location is secure and dry and has adequate ventilation. The temperature range of a suitable
location is within 32–122 degrees F (0-50 degrees C), and the relative humidity is less than 90 percent
non-condensing .
1.2
Inventorying The Tools And Hardware
Round-head wood screws (typically
Round-head wood screws (typically
necessary if fasteners must also pass through a dry-wall covering)
Cross recessed screwdriver (phillips-head type)—to match front panel shipping screws
Flat blade screwdriver—to match front panel retaining screws
Electric drill—if prepared holes are required
Connecting tool—for fastening wires to a type–66 connector block.
Crimping tool—for 623-type modular plugs
Static discharge wrist strap and conductive floor mat
1.3
Complying With Underwriters Laboratories Regulations
Per The Underwriters Laboratories regulation 1459, 2nd edition, be aware of the following precautions when
installing telephone equipment that is to be directly connected to the telephone company network:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the
network interface.
Use caution when installing or modifying telephone lines.
This manual has been developed by Comdial Corporation (the "Company") and is intended for the use of its customers and service personnel. The information in this manual is subject to change without notice.
While every effort has been made to eliminate errors, the Company disclaims liability for any difficulties arising from the interpretation of the information contained herein.
The information contained herein does not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation, or maintenance.
Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser's purposes, contact Comdial, Inside Sales Department, Charlottesville, Virginia
22906.
Printed in U.S.A.

Installing The

1
/
x 1–inch for mounting equipment cabinet to backboard)
4
1
1
/
x 1
/
–inch for mounting backboard to wall studs; longer screws are
4
2
R
IMI66-105.02
7/95