Connecting Data Devices - Comdial DXP Plus Manual

Comdial digital communications system manual
Hide thumbs Also See for DXP Plus:
Table of Contents

Advertisement

IMI66–105

4.0 Connecting Data Devices

The system provides two short-run serial data ports on the CPU board. The system designates these modular jacks
as Modem and Maintenance. These two serial data ports are dedicated to the personal computer (PC) that you will
use to load the programmed data base and to the remote servicing and programming modem that you will use to
remotely load the programmed data base and troubleshoot the system. Since these serial data ports are short-run,
you must keep the cabled distance between the data device and the data port to 25 feet or less.
NOTE: If you connect a modem other than the DXMDM, you must interface that modem through a comunications
card that you have installed on the services board or an auxiliary board.
When you are not using a PC for programming purposes, you should disconnect it from the maintenance
port. It is possible for the idle connected PC to induce electrical interference that may affect system
performance.
Remember, a data cable must be no longer than 25 feet in length. When preparing a data cable for connection to a
data device, refer to the manufacturer's manual for the equipment being interfaced and make the following wiring
connections:
Wire the common equipment RD (data from device to common equipment) connection to the device TD
(transmit data) connection.
Wire the common equipment TD (data to device from common equipment) connection to the device RD
(receive data) connection.
Wire the common equipment SG (signal ground) connection to the device SG (signal ground) connection.
If required for proper operation, wire the common equipment CTS (clear-to-send status from device to common
equipment) connection to the device RTS (request-to-send) connection.
NOTE: The common equipment requires a positive voltage, with respect to signal ground, in order to send data.
If the cable has spare wires, be sure to ground them so that they will not act as antennas and induce interference
into the system. Further, if there is a source of RF power nearby (such as a radio transmitter), use shielded cable
and ground the shield at both ends.
The default data format is shown in the following chart. Configure the data device that you connect to the
maintenance port to match the charted information.
As an added precaution against induced interference, route the data cable as far away from any
fluorescent lighting as you can reach, and make every effort to route the data cable perpendicular to other
wiring.
16 – Installing The DXP Plus Main Cabinet
Port Type
Baud Rate Data Bit Stop Bit
Maintenance Port
9600
Modem Port
2400
Installing The DXP Plus Main Cabinet
CAUTION
8
1
8
1
CAUTION
Parity Bit
0
0

Hide quick links: