Requesting Cold Start Information - Comdial DXP Plus Manual

Comdial digital communications system manual
Hide thumbs Also See for DXP Plus:
Table of Contents

Advertisement

IMI89–207
4.2

Requesting Cold Start Information

When the DXP-T1 system is turned on, internal self-tests are run to determine the condition of the
system. When you use this request, you are asking the system to provide you with the results of these
tests. Upon making the cold start information request, the system verifies the following.
operating mode is superframe (SF) or extended superframe (ESF),
FDL daughterboard (used for ESF) is installed on the T1 board and okay or not installed (or defective),
channel capacity currently selected is 8, 16, or 24 channels,
static RAM is okay or has read/write errors,
internal CPU RAM is okay or has read/write errors.
4.2.1 Setting The DIP Switches For Cold Start Information
Set the DIP switches as shown in the following table. Switch 1 is the top switch. When the switch is
moved to the right, it is turned on. The hex code shown is used for remote operation only.
SWITCH SETTINGS
1
2
3
ON ON ON OFF OFF OFF OFF ON
4.2.2 Reading The Cold Start Information From The LEDs
The Table below shows the cold start information that is revealed by the LEDs. LED 1 is at the top.
1
2
3
OFF
OFF
ON
OFF
Example: If you see the following LED light pattern, you can determine the cold start results from the above
LED definitions. (For remote testing, the lFDL board recognized system would send hex code 53.)
m
= LED off and
m
|
= ESF mode
m
|
= FDL board recognized
m
= 24-channel
m
capacity
|
= static RAM fully operational
|
= internal CPU RAM fully operational
14 – Troubleshooting The DXPT1 Installation
4
5
6
7
8 Provide results of all self-tests run during
LEDs
4
5
6
7
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
|
= LED on
Troubleshooting The DXPT1 Installation
TYPE OF REQUEST
system start-up (cold start).
LED DEFINITIONS
8
Not used
SF mode
ESF mode
Always off
Either in SF mode or FDL board missing or bad
FDL board recognized (ESF only)
Selected channel capacity is 24
Selected channel capacity is 8
Selected channel capacity is 16
Static RAM has read/write errors
Static RAM is okay
Internal CPU RAM has read/write errors
ON
Internal CPU RAM is okay
HEX
CODE
E1
^
^

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents