Dc Power Cable Specifications For Mx204 Router; Dc Power Cable Lug Specifications; Dc Power Cable Specifications - Juniper MX204 Hardware Manual

Universal routing platform
Hide thumbs Also See for MX204:
Table of Contents

Advertisement

DC Power Cable Specifications for MX204 Router

IN THIS SECTION

DC Power Cable Lug Specifications | 45

DC Power Cable Specifications | 45

DC Power Cable Lug Specifications
The accessory box shipped with the router includes the cable lugs that attach to the terminal of each
power supply.
Figure 15: DC Power Cable Lug
.25
.84
All measurements in inches
CAUTION:
Before router installation begins, a licensed electrician must attach a cable
lug to the grounding and power cables that you supply. A cable with an incorrectly
attached lug can damage the router.
DC Power Cable Specifications
You must supply four DC power cables that meet the following specifications: 14-16 AWG (2.08 - 1.3 mm
minimum 60° C wire, or as required by the local code.
SEE ALSO
.15 dia
.170 max
wire diameter
(insulation)
.71
45
2
),

Hide quick links: