After Ethernet OAM connections are established, the link monitoring periods and thresholds configured
in this section take effect on all Ethernet ports automatically.
Configuring Errored Frame Event Detection
An errored frame event occurs when the number of detected error frames over a specific interval
exceeds the predefined threshold.
Follow these steps to configure errored frame event detection:
To do...
Enter system view
Configure the errored frame
event detection interval
Configure the errored frame
event triggering threshold
Configuring Errored Frame Period Event Detection
An errored frame period event occurs if the number of frame errors in specific number of received
frames exceeds the predefined threshold.
Follow these steps to configure errored frame period event detection:
To do...
Enter system view
Configure the errored frame
period event detection period
Configure the errored frame
period event triggering
threshold
Configuring Errored Frame Seconds Event Detection
An errored frame seconds event occurs when the number of error frame seconds detected on a port
over a detection interval exceeds the error threshold.
Follow these steps to configure errored frame seconds event detection:
To do...
Enter system view
Configure the errored frame
seconds event detection
interval
Use the command...
system-view
oam errored-frame period
period-value
oam errored-frame threshold
threshold-value
Use the command...
system-view
oam errored-frame-period
period period-value
oam errored-frame-period
threshold threshold-value
Use the command...
system-view
oam errored-frame-seconds
period period-value
1-7
Remarks
—
Optional
1 second by default
Optional
1 by default
Remarks
—
Optional
1000 milliseconds by default
Optional
1 by default
Remarks
—
Optional
60 second by default