Omron E5AN-H User Manual page 333

Digital controllers
Hide thumbs Also See for E5AN-H:
Table of Contents

Advertisement

(2) Unless the Program Pattern parameter is set to OFF, the bank number will be from 0 to the value
set for the Valid Program Bank parameter.
Adjustment Level
Parameters
Characters
l.adj
Adjustment Level
Display
at
AT Execute/Cancel
cmwt
Communications
Writing
irdr
Infrared Communica-
tions Use
spmd
SP Mode
ct1
Heater Current 1
Value Monitor
hb1
Heater Burnout
Detection 1
oc1
Heater Overcurrent
Detection 1
ct2
Heater Current 2
Value Monitor
hb2
Heater Burnout
Detection 2
oc2
Heater Overcurrent
Detection 2
lcr1
Leakage Current 1
Monitor
hs1
HS Alarm 1
lcr2
Leakage Current 2
Monitor
hs2
HS Alarm 2
hb1
Heater Burnout
Detection 1
hb2
Heater Burnout
Detection 2
sp-0
SP 0
sp-1
SP 1
sp-2
SP 2
sp-3
SP 3
ins
Temperature Input
Shift
insh
Upper Limit Temper-
ature Input Shift
Value
insl
Lower Limit Temper-
ature Input Shift
Value
312
Setting (monitor) value
OFF: AT Cancel
AT-2: 100%AT Execute
AT-1: 40%AT Execute (See
note 3.)
OFF, ON
OFF, ON
LSP, RSP
0.0 to 55.0
0.0 to 50.0
0.0 to 50.0
0.0 to 55.0
0.0 to 50.0
0.0 to 50.0
0.0 to 55.0
0.0 to 50.0
0.0 to 55.0
0.0 to 50.0
0.0 to 50.0
0.0 to 50.0
SP lower limit to SP upper
limit
SP lower limit to SP upper
limit
SP lower limit to SP upper
limit
SP lower limit to SP upper
limit
−199.99 to 32400
−199.99 to 32400
−199.99 to 32400
Display
Default
off,
OFF
at-2,
at-1
off, on
OFF
off, on
OFF
lsp, rsp
LSP
0.0
50.0
0.0
50.0
50.0
50.0
0.0
0.0
0
0
0
0
0.00
0.00
0.00
Appendix
Unit
Set value
None
None
None
None
A
A
A
A
A
A
A
A
A
A
A
A
EU
EU
EU
EU
°C or °F
°C or °F
°C or °F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5cn-hE5en-h