Advanced Function Setting Level
spdp
PV/SP Display Screen Selection
Function
Setting
Note
See
See
odsl
MV Display Selection
Function
Setting
• This parameter sets the PV/SP Screen No. 3 display and order of display.
• The default is 4.
Set value
0
1
2
3
4
5
6
7
The MV for heating and cooling control is set in the MV Display Selection
parameter.
■ Related Parameters
Process value/set point (operation level): Page 177
MV display selection (advanced function setting level): Page 275
• This parameter selects the MV display for PV/SP/MV during heating and
cooling control. Either heating MV or cooling MV can be selected.
Setting range
o: MV (heating)
c-o: MV (cooling)
The No. 3 display must be supported
(E5AN/EN-H).
Display contents
Only PV/SP is displayed (with no No. 3 display).
PV/SP/Bank No. and PV/SP/MV are displayed in order.
(See note.)
PV/SP/MV and PV/SP/Bank No. are displayed in order.
(See note.)
Only PV/SP/Bank No. is displayed.
PV/SP/MV is displayed (See note.)
PV/SP/Bank No. and PV/SP/Soak time remain are dis-
played in order.
PV/SP/MV and PV/SP/Soak time remain are displayed in
order. (See note.)
Only PV/SP/Soak time remain is displayed.
The No. 3 display must be supported
(E5AN/EN-H).
Heating and cooling control must be
used.
The PV/SP Display Screen Selection
parameter must be set to 1, 2, 4, or
6, or the Monitor/Setting Item 1 to 5
parameter must be set to 2.
Default
o
Section 5-10
275