I/O Configuration and Main Functions
Control Outputs
Alarms
Control Adjustment
Event Inputs
Heater Burnout, HS Alarm,
and Heater Overcurrent
Communications
Functions
Note
• A control output can be a relay output, voltage output (for driving SSR),
linear voltage output, SSR output, or current output, depending on the
model.
• With the E5CN-H@2@@, auxiliary output 2 is used as control output (cool-
ing) when heating/cooling control is selected. (It is also possible to allo-
cate a different output.) Therefore, use auxiliary output 1 if an auxiliary
output is required while using heating/cooling control.
• Set the alarm type and alarm value or the alarm value upper and lower
limits.
• If necessary, a more comprehensive alarm function can be achieved by
setting a standby sequence, alarm hysteresis, auxiliary output close in
alarm/open in alarm, alarm latch, alarm ON delay, and alarm OFF delay.
• If the Input Error Output parameter is set to ON, the output assigned to
alarm 1 function will turn ON when an input error occurs.
• If the Remote SP Input Error Output parameter is set to ON, the output
assigned to the alarm 1 function will turn ON when an input error occurs.
• Optimum PID constants can be set easily by performing AT (auto-tuning)
or ST (self-tuning).
• With the E53-CN@B@N2 for the E5CN-H (for two event inputs), the
E5AN/EN-H@B@M@-500 for E5AN/EN-H (for two event inputs) or the
E5AN/EN-H@B@M@-500 with the E53-AKB for the E5AN/EN-H (for four
event inputs), the following functions can be executed using event inputs:
switching banks, switching RUN/STOP, switching between automatic and
manual operation, starting/resetting the program, inverting direct/reverse
operation, switching SP modes, 100% AT execute/cancel, 40% AT exe-
cute/cancel, setting change enable/disable, communications writing
enable/disable and canceling the alarm latch.
• With the E53-CN@H@N2 or E53-CN@HH@N2 for the E5CN-H, or the
E5AN/EN-H@@H@-500 or E5AN/EN-H@@HH@-500, the heater burnout
detection function, HS alarm function, and heater overcurrent detection
function can be used.
• Communications functions utilizing CompoWay/F (See note 1.), SYSWAY
(See note 2.), or Modbus (See note 3.) can be used.
RS-485 Interface
Use the E53-CN@03N2 for the E5CN-H, or the E53-EN03 for the E5AN/
EN-H.
RS-232C Interface
Use the E53-CN@01N2 for the E5CN-H, or the E53-EN01 for the E5AN/
EN-H.
RS-422 Interface
Use the E53-EN02 for the E5AN/EN-H.
(1) CompoWay/F is an integrated general-purpose serial communications
protocol developed by OMRON. It uses commands compliant with the
well-established FINS, together with a consistent frame format on
OMRON Programmable Controllers to facilitate communications be-
tween personal computers and components.
(2) SYSWAY communications do not support alarm 3.
(3) Modbus is a communications control method conforming to the RTU
Mode of Modbus Protocol. Modbus is a registered trademark of
Schneider Electric.