Renault Duster 2007 Manual page 804

Table of Contents

Advertisement

NOTES
Parameter or Status
Computer
ET298: Low-speed fan
Injection
ET299: High-speed fan
conditioning request
MR-453-X79-62C000$060.mif
V1
CLIMATE CONTROL
Fault finding – Conformity check
Only carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: Engine at idle speed, AIR CONDITIONING OPERATING
(air conditioning compressor engaged).
SUB-FUNCTION: COLD LOOP (CONTINUED)
Checked or Action
assembly
assembly
ET018: Air
Display and notes
ACTIVE if the refrigerant
pressure is less than
19 bar,
INACTIVE otherwise.
ACTIVE if the refrigerant
pressure is more than
19 bar,
INACTIVE otherwise.
ACTIVE / YES
62C-29
62C
Fault finding
In the event of a fault, refer
to the interpretation of
this status.
In the event of a fault, refer
to the interpretation of
this status.
In the event of a fault, refer
to the interpretation of
this status.

Advertisement

Table of Contents