Parameter or Status
Computer
UCH
ET091: Engine running
(depending on version)
Injection
(depending on version)
absorbed by the AC*
*AC: Air conditioning
MR-453-X79-62C000$060.mif
V1
CLIMATE CONTROL
Fault finding – Conformity check
Only carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: Engine at idle speed, AIR CONDITIONING OPERATING
(air conditioning compressor engaged).
SUB-FUNCTION: COLD LOOP
Checked or Action
ET321: Air
conditioning
compressor
PR037: Refrigerant
pressure
PR055 or PR145:
Engine speed
PR064: Coolant
temperature
PR089 or PR155:
Vehicle speed
PR125: Power
compressor
Display and notes
YES
ACTIVE
1 bar < X < 27 bar
750 rpm < X < 850 rpm
X = engine coolant temperature
0 mph
300 W < X < 5000 W
(ambient temperature 23 ºC)
62C-28
62C
Fault finding
In the event of a fault, refer
to the interpretation of
this status.
If the status displays
INACTIVE, refer to the
interpretation of this
status.
If there is a fault, see the
interpretation of this
parameter
If there is a fault, see the
interpretation of this
parameter
If there is a fault, see the
interpretation of this
parameter
If there is a fault, see the
interpretation of this
parameter
If there is a fault, see the
interpretation of this
parameter

Advertisement