Renault Duster 2007 Manual page 800

Table of Contents

Advertisement

NOTES
Computer
Injection
*AC: Air conditioning
MR-453-X79-62C000$060.mif
V1
CLIMATE CONTROL
Fault finding – Conformity check
Only carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application conditions: Engine stopped, ignition on, AIR CONDITIONING
SWITCHED OFF (Passenger compartment blower unit switched off and air conditioning
compressor not activated).
Note:
Read the parameters when the vehicle is cold (in the morning) to check the conformity
of the temperature parameters (without thermometer). The two temperatures should be
approximately equal (interior, exterior and engine coolant).
SUB-FUNCTION: COLD LOOP (CONTINUED)
Parameter or Status
Checked or Action
PR125: Power absorbed
by the AC* compressor
ET298: Low-speed fan
assembly
ET299: High-speed fan
assembly
ET018: Air conditioning
request
Display and notes
0 W (ambient tº = 23ºC)
INACTIVE
INACTIVE
INACTIVE / NO
62C-25
62C
Fault finding
If there is a fault, refer to
the interpretation of this
parameter.
In the event of a fault, refer
to the interpretation of
this status.
In the event of a fault, refer
to the interpretation of
this status.
In the event of a fault, refer
to the interpretation of
this status.

Advertisement

Table of Contents
loading