3-25 ENGINE
▣ ▣ VALVE HEAD RADIAL RUNOUT
Support the valve using a v-block and measure the
valve head radial runout using the dial gauge, as
shown. If the runout exceeds the service limit,
replace the valve with a new one.
Valve head radial
Cylinder head
runout
distortion
Dial gauge : 09900-20606
Magnetic stand : 09900-20701
V-block : 09900-21304
▣ ▣ VALVE STEM DEFLECTION
Lift the valve about 10 mm (0.39 in) from the valve
seat. Measure the valve stem deflection in two direc-
tions, "X" and "Y", perpendicular to each other.
Position the dial gauge as shown.
If the deflection exceeds the service limit, determine
whether the valve or the guide should be replaced
with a new one.
Valve stem deflection
IN.
EX.
Dial gauge : 09900-20606
Magnetic stand : 09900-20701
▣ ▣ VALVE STEM DIAMETER
Measure the valve stem outside diameter using the
micrometer.
If the diameter measured exceeds the standard,
replace the valve.
Valve stem diameter
IN.
4.975 ~ 4.990 mm (0.1959 ~ 0.1965 in)
EX.
4.955 ~ 4.970 mm (0.1951 ~ 0.1957 in)
Micrometer(0~25 mm) : 09900-20201
Service limit
0.35 mm (0.014 in)
Service limit
0.35 mm
(0.014 in)
0.35 mm
(0.014 in)
Standard

Hide quick links: