Installing The Analog Terminal Adapter (Ata) - Nortel Meridian SL-100 Reference Manual

Meridian modular telephones
Hide thumbs Also See for Meridian SL-100:
Table of Contents

Advertisement

MCA installation
1
2
3
4
5
6

Installing the analog terminal adapter (ATA)

Procedure describes the analog terminal adapter (ATA) installation
procedures for Meridian modular telephones (M2006, M2008, M2008HF,
Meridian SuperNode MSL-100 Meridian Modular Telephones Reference Manual MSL11
For NT2K sets, install the jumper board with the black connector (P1) onto the
2x7 pin connector (the jumper is keyed for orientation).
Install the MCA in the footstand:
Tilt the MCA PC board so that the DB-25 connector fits into the break-out
section.
Lower the board into position on the bottom of the footstand.
Secure the board using the two screws provided.
Plug one end of the short 8-conductor line cord, provided with the MCA, into the
data jack in the base of the telephone. Plug the other end of this cord into
connector J1 on the MCA.
Reassemble the footstand onto the base using the four screws you removed.
WARNING
Risk of equipment failure
Use only the Class 2 power source included with your
MCA. Specifications:
The transformer that accompanied the earlier MCA prior
to April 24, 1998, MPDA or external alerter interface
board does not work with the MCA dated after April 24,
1998.
Reconnect all cords, including the handset cord and new 24Vac wall
transformer.
Locate the label that was included with the MCA, and place it on the telephone
base close to the existing set label for future tracking purposes.
You are now ready to connect your ASCII terminals or personal computer to
your telephone. Refer to the manufacturer directions for installation
instructions.
The MCA installation procedure is complete.
NT A0367335
Input rated: 120 Vac, 50-60Hz, 23 watts
Output rated: 24 Vac, 600 mA, and 8 Vac, 400
mA
Installation procedures 2-11