Error code in Gn_XIST2
Table 10- 18 Error code in Gn_XIST2
n_XIST2
Meaning
1
Encoder fault
2
Zero mark monitoring
3
Abort parking sensor
4
Abort reference mark
search
5
Abort, retrieve reference
value
6
Not relevant
7
Abort get measured value
8
Abort absolute value
transmission on
3841
Function not supported
10.10.1.3
Encoder 2 actual position value 1 (G2_XIST1)
● See G1_XIST1
10.10.1.4
Encoder 2 actual position value 2 (G2_XIST2)
● See G1_XIST2
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
One or more existing encoder faults.
Detailed information in accordance with drive messages.
–
Parking drive object already selected.
A fault exists (Gn_ZSW.15 = 1)
Encoder has no zero marker (reference mark)
Reference mark 2, 3 or 4 is requested
Command "Read value x" set during search for reference mark
Inconsistent position measured value with distance-coded reference marks.
More than four values requested
No value requested
Requested value not available
-
More than one value requested
No value requested.
Requested value not available
Parking encoder active
Parking drive object active
Absolute encoder not available
Alarm bit absolute value protocol set
–
Possible causes / description
Descriptions of functions
10.10 Encoder evaluation
413